![ColorKey MicroPar HEX 7 User Manual Download Page 12](http://html1.mh-extra.com/html/colorkey/micropar-hex-7/micropar-hex-7_user-manual_2637955012.webp)
10
Ø
Press UP / DOWN until “Pr- -“ is displayed.
Ø
Press ENTER to proceed. Display will flash indicating you have entered edit mode.
Ø
Press UP / DOWN until desired selection is displayed (see chart below “Pr- -“).
Ø
Press ENTER to save and store your selections. The screen will stop flashing
indicating you have exited edit mode.
Built-in Program Chart:
Ø
Pr32 - Pr35 are speed adjustable. SP00 is the fastest, SP15 is the slowest.
Ø
Pr00 - Pr63
:
R,G,B,A,W,UV single color or multi-colors lighting
Ø
Pr64 - 6 Color Change mode
Ø
Pr65 - 6 Color Strobe
Ø
Pr66 - Multi-Color Change
Ø
Pr67 - Multi-Color Strobe
3. White balance setting
(
UtSt
)
Ø
Press MENU to activate display / return to ‘main menu’ screen.
Ø
Press UP/DOWN until “UtSt” is displayed.
Ø
Press ENTER to proceed. Display will flash indicating you have entered edit mode.
Ø
Press UP/DOWN until desired selection is displayed (from 0 to 255).
Ø
Press ENTER to save and store your selections. The screen will stop flashing
indicating you have exited edit mode.
Note*** USon indicates white balance function is on. USoF indicates white balance function
is off. SEon indicates the transfer of white balance data to other matching fixtures. SEoF
indicates invalid. rEt indicates save and exit. When white balance data is set, press UP or
DOWN until “rEt” is displayed and press ENTER to select and store your selections.
Note*** Changing the white balance data controls the output of selected colors. For example,
if r000 is set, when switching the white balance function to ‘On,’ there will be no red color
output.