Page | 11
TXF
4. Site Requirements
Environmental Requirements
The printer should be installed in a clean, dust-free environment, with temperature and relative humidity
range which are given as below:
•
Power ON
:
Temperature
: 20 to 28
0
C
Humidity
: 60 to 70%RH (Non-condensing)
•
Power OFF
:
Temperature
: 5 to 40
0
C
Humidity
: 20 to 80%RH (Non-condensing)
Room Requirements
The room requirements are given as follow:
•
Room dimensions (Length x Width x Height) should be 22'x18'x12' (Feet)
•
Room temperature should be maintained in range 20-28 Degree Celsius with humidity 60-70% RH
Note:
Printer is equipped with dryers thus it may raise the room temperature.
•
Room should be closed dirt-free
•
Cool Day White lighting should be used for proper color balance
•
Water inlet and outlet pipe fittings 1” BSP
•
Recommended RO water supply
•
Ball Cock should be fitted at the Water inlet in water tank
•
Float Valve fitting inside reservoir is recommended
•
Water Inlet should be 20LPM (Liters Per Minute)
Drainage Tubing ID should be minimum of 25mm
Power Requirements
The power requirements are given as follow:
•
Power requirements must be 220V, 24A Single Phase 50Hz (Three Phase Load Distribution)
•
1nos. 16 Amp power cords should be required
•
2nos. 6 Amp power outlet are required for print engine and computer system.
•
Three Phase connection should be required to balance the load of heaters in each phase
The detailed power consumption are given as follow:
•
Print Engine:
o
Power Input 1:
For Print engine & Belt System
o
Total Wattage:
120 20% @ 220Volts AC 50Hz
o
Sinewave
: Max 1800Watts
•
Print Dryer:
o
Power Input 2:
For IR Heater
o
Total Wattage:
200 20% @ 220Volts AC 50Hz
o
Sinewave:
Max 2400Watts
•
Belt Dryer:
o
Power Input 3:
For Belt Dryer cum Glue Activator
o
Total Wattage:
150 20% @ 220Volts AC 50Hz
o
Sinewave:
Max 2000Watts