12 

 

TROUBLESHOOTING 

 
 

Malfunction   

Reasons 

Remedy/Solutions  

- The indicator doesn’t 
light  

- No power  
- The master control goes wrong 
- The fuse is burnt 
- The panel goes wrong   

-  Check the circuit 
-  Change the master control board 
-  Change the fuse      
-  Change the panel   

- Out of control     

- Interfered by power 
- Interfered by environment   
- The panel goes wrong 

- Power Off 
- Remove or keep away from 
interference  
- Change the panel    

- The display is 
normal but without 
wind or the wind 
speed is too low   

- The fan gets stuck 
- The water screen or dust net is 
blocked     
- The fan is distorted           
- The master control board goes 
wrong 
  

-  Check the machine fixing hoop 

and fan 

-  Clean/change the water screen 

or the dust net  

-  Change the fan 
-  Change the master control board 

- The motor is out of 
control  

- The master control board goes 
wrong 
- The panel goes wrong 

- Change the master control board 
- Change the panel  

- Water leak at the 
drainage valve   

- The induction valve is damaged 
- The draining valve is damaged 
- The master control board goes 
wrong 

- Change the induction valve  
- Change the draining valve  
- Change the master control board 

 

NOTE:

  This  instruction  chart  is  for  references  purposes  only.  If  any  technical  assistance  is 

needed, call supplier’s qualified service center.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CLAC-150

Page 1: ...www colorato net INSTRUCTION MANUAL AIR COOLER MODELS CLAC 350 CLAC 150 Thank you for buying the AIR COOLER COLORATO Read carefully these Instructions before using the appliance...

Page 2: ...ICATION 3 TECHNICAL SPECIFICATION 4 SPECIAL FEATURES 4 ADDED FEATURES 5 IMPORTANT REMINDERS 5 CAUTION 6 CONTROL PANEL P C B ILLUSTRATION 7 DISPLAY DIAGRAM 7 CONTROL FUNCTIONS 8 OPERATING PROCEDURE 8 E...

Page 3: ...operation instruction manual due to continuous product upgrade Although there may be slight differences between the actual product and the one used in illustration it will not in any way affect the p...

Page 4: ...igh technology The basic theory for reducing the heat is water evaporation that carries all the heat of the surrounding area and reduces the air s temperature The water is continuously wetting the coo...

Page 5: ...ling pad energy saving and environment friendly Big capacity water tank for more operating hours Optimizing air quality through silent wind Truckle Wheel with brake for easy transport Tri dimension ci...

Page 6: ...ad the guide book carefully and operate according to the instructions Use the machine in the following conditions Temperature 18 C 45 C Water Temperature 45 C The electric voltage must not exceed the...

Page 7: ...rol wire randomly is not allowed If abnormality occurred during transportation contact your supplier Don t use wrong fuse or other line as it may cause malfunction on the unit or and fire accident WAR...

Page 8: ...7 CONTROL PANEL P C B ILLUSTRATION DISPLAY DIAGRAM...

Page 9: ...m HIGH MED LOW MODE SLEEP Mode When setting mode SLEEP from HIGH fan speed after half hour the machine will run on MED fan speed and after half hour again It always keeps on LOW fan speed without chan...

Page 10: ...after half hour again It always keeps on LOW fan speed without changing 9 Press TIMER to activate timer function 10 Press LCD to activate the LCD function 1 When connecting the power supply the LCD li...

Page 11: ...10...

Page 12: ...er but NEVER USE PRESSURIZED WATER as it may damage the pad Wash from inner side to the outside of pad inner side is the side facing the fan motor NEVER USE ANY LIQUID CLEANER DETERGENT as it may dama...

Page 13: ...r dust net is blocked The fan is distorted The master control board goes wrong Check the machine fixing hoop and fan Clean change the water screen or the dust net Change the fan Change the master cont...

Page 14: ...13 HEALTHY AND COMFORTABLE FUNCTION ENERGY SAVING ENVIRONMENTAL FRIENDLY...

Reviews: