12
TROUBLESHOOTING
Malfunction
Reasons
Remedy/Solutions
- The indicator doesn’t
light
- No power
- The master control goes wrong
- The fuse is burnt
- The panel goes wrong
- Check the circuit
- Change the master control board
- Change the fuse
- Change the panel
- Out of control
- Interfered by power
- Interfered by environment
- The panel goes wrong
- Power Off
- Remove or keep away from
interference
- Change the panel
- The display is
normal but without
wind or the wind
speed is too low
- The fan gets stuck
- The water screen or dust net is
blocked
- The fan is distorted
- The master control board goes
wrong
- Check the machine fixing hoop
and fan
- Clean/change the water screen
or the dust net
- Change the fan
- Change the master control board
- The motor is out of
control
- The master control board goes
wrong
- The panel goes wrong
- Change the master control board
- Change the panel
- Water leak at the
drainage valve
- The induction valve is damaged
- The draining valve is damaged
- The master control board goes
wrong
- Change the induction valve
- Change the draining valve
- Change the master control board
NOTE:
This instruction chart is for references purposes only. If any technical assistance is