background image

 

 

R

OTA

 400

 

 

Collomix GmbH 

 

 

D-85080 Gaimersheim 

 

8

 

Version G 1.5-18 

 

3.3

 

Foreseeable Misuse 

Any reasonably foreseeable misuse, which can be hazardous for the user, third parties, or for the 

biaxial mixer are: 

 

 

The use of the biaxial mixer and its accessories contrary to the intended use. 

 

The use of damaged containers or containers not suitable for mixing.  

 

The mixing of explosive substances. 

 

The use of substances, which react chemically with one another; in particular, expanding 

substances. 

 

The use of the equipment outside  the physical use limitations described in the Chapter 

"Commissioning / Operating". 

 

The modification of the control software without the prior coordination with Collomix GmbH. 

 

Modifications on the biaxial mixer as well as add-ons and retrofits without the prior coordination 

with Collomix GmbH. 

 

Operating the system contrary to the requirements of the Operating Instructions concerning 

safety information, installation, operation, servicing, and maintenance, set-up, and 

malfunctions. 

 

Bridging or decommissioning of safety and protective actions of the system. 

 

Operating the system if malfunctions are obvious / with obvious malfunctions  

 

Repair, cleaning, and maintenance work without disconnecting the system from power. 

 

WARNING 

Danger of injury through improper modifications 

Hazards exist through unauthorized modifications to the system and the use of third party spare 

parts.  

 

Use only original spare parts and accessories of the manufacturer. 

 

Do not change, add to, or retrofit the system without the consent of the manufacturer. 

 

 

 

3.4

 

Qualifications of operating personnel 

These Operating Instructions are directed toward operators and personnel with the following areas 

of competency: 

 

Working area 

Expertise 

Installation, transport and storage 

Specialised staff 

Commissioning, decommissioning 

Trained personnel 

Operation 

Trained personnel 

Servicing and maintenance 

Specialised staff 

Troubleshooting 

Specialised staff 

Definition acc. to DIN EN 60204-1: 
Trained personnel: 

A person, who was instructed by an expert in the responsibilities he or she has been assigned and 

any possible hazards in case of improper behaviour and a person, who was trained in the necessary 

protective devices and protective actions, if needed. 

Expert staff: 

Persons who can evaluate the work assigned to them and recognize possible dangers on the basis of 

their specialised training, knowledge, experience, and familiarity with the relevant norms. 

Summary of Contents for Rota 400

Page 1: ...Version G 1 5 18 Instructions Biaxial Mixer ROTA 400 Keep this manual within immediate reach of the machine Translation of the original instructions en Englisch...

Page 2: ...ROTA 400 Collomix GmbH D 85080 Gaimersheim 2 Version G 1 5 18...

Page 3: ...10 5 1 Content 10 5 2 Transport 10 5 3 Set up the equipment 10 5 4 Trial run 10 6 Operation 11 6 1 Switching on the machine 11 6 2 Load a container 11 6 3 Starting the mixing cycle 12 6 4 Ending the...

Page 4: ...omponents Machine components 1 Screw for transport roller 7 Manual door release 2 Line connector and main fuse 8 Control panel 3 Upper clamping plate 9 Door 4 Control system fuse 10 Lower clamping pla...

Page 5: ...ersion G 1 5 18 5 1 2 Operating and display components Button for DOOR OPEN door Button E OPEN the mixing unit STOP stop mixing cycle prematurely ACKNOWLEDGE messages Button I Mixing cycle I Button II...

Page 6: ...ntion to the corresponding precautionary measures WARNING This signal word is used if death or severe physical injuries may result from not paying attention to the corresponding precautionary measures...

Page 7: ...ase read these Operating Instructions before working with the machine Keep the Operating Instructions within immediate reach of the machine Please hand the Operating Instructions to any subsequent own...

Page 8: ...ous with obvious malfunctions Repair cleaning and maintenance work without disconnecting the system from power WARNING Danger of injury through improper modifications Hazards exist through unauthorize...

Page 9: ...ne if needed 3 6 Residual Risks If all precautions are taken there may be obvious residual risks Adhering to the safety instructions the designated use and the operating instructions as a whole can re...

Page 10: ...machine the applicable electrical requirements and the additional information in this Operating Instructions must be followed The machine is delivered on a wooden pallet packaged in recyclable cardbo...

Page 11: ...to work with it 6 1 Switching on the machine The machine is turned on using the main switch 5 After an automatic initialisation READY is shown on the display Any errors detected during initialisation...

Page 12: ...tch In dangerous situations the machine can be turned off with the EMERGENCY STOP switch After the EMERGENCY STOP button is pressed the mixing unit will coast to a standstill and remain in this positi...

Page 13: ...positioned and fixed with the help of Button I Auto 6 5 3 MANU With the mixing container unclamped the mixing unit must be positioned manually Upon actuation of Button III MANU the door can be opened...

Page 14: ...e if necessary adjust E070 Mixing Unit locked Latching pin blocked The latching pin is blocked clean and lubricate replace if necessary Latching pin released Check the lead connector to the switch of...

Page 15: ...of the door lock Check door motor E190 Fuse blown Turn the machine off and wait one minute until the fuse can be pushed in again The grey highlighted services can only be carried out by trained techni...

Page 16: ...the threaded spindles and lubricate with Mobilux EP2 Check the timing belt for wear and tear Age conditioned lengthening of the timing belt is indicated by a twisted clamping plate 10 Elongating can...

Page 17: ...ntentional tilting and instability 9 2 Disposal The transport package is made of recyclable material Please dispose this material accordingly At the end of the useful life the machine must be properly...

Page 18: ...eter max 360mm Machine weight 215kg Dimensions w x d x h 780 987 1186mm Noise emission in accordance with 2006 42 EG Sound pressure level LpA 64dB re 20 Pa Sound power level LWA 75dB re 1pW Uncertaint...

Page 19: ...ordance with the requirements of the guidelines 2006 42 EC 2004 108 EC 19 04 2016 2014 30 EU 20 04 2016 2011 65 EU Please request technical information from Collomix GmbH Abt Technische Entwicklung Da...

Page 20: ...ROTA 400 Collomix GmbH D 85080 Gaimersheim 20 Version G 1 5 18 Collomix GmbH Daimlerstr 9 D 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 www collomix de...