Collins 516F-2 Converting Instructions Download Page 3

polarity) and wrapping the legs of one diode around the other, trimming and then soldering the wrapped 
legs to the straight diode legs. 

 

(  ) 

Attach the meter protection diode assembly directly across the meter studs in the transceiver (KWM-2) or 
transmitter (32S-1/3), whichever may be the case. This protects the meter from slamming against the pin 
when first turned on. Leave any capacitor that may be connected across the meter studs. 

(  ) 

Check all of your wiring and make sure the modifications have been properly installed before applying 
power.  You may want to check the output voltages of the supply before re-installing in the outer cabinet. 

(  ) 

Replace the power supply chassis back in the outer cabinet and re-connect all cables and switch power on. 

Adjust R-9 bias potentiometer (right rear of the supply) for proper static current on the 6146's 
(approximately 40-50 mA).

 

For reference, the schematic diagram of the solid-state 516F-2 power supply is shown below: 

 

Special thanks to John May, K6MAY, for the use of this information. 

 
 

HARBACH ELECTRONICS, LLC 

Jeff Weinberg – W8CQ 

468 County Road 620 

Polk, OH  44866-9711 

(419) 945-2359 

http://www.harbachelectronics.com

 

[email protected]

 

3

 

 