5005749-CTG-A-0216
36
Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
TH4B1821S
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
AIR TEMP.
ENTERING
INDOOR COIL (°F)
ID CFM
450
600
750
MBH
COP
KW
MBH
COP
KW
MBH
COP
KW
60
60
21.9
4.08
1.57
22.7
4.41
1.51
23.6
4.76
1.45
70
21.3
3.63
1.72
22.1
3.93
1.65
22.9
4.25
1.58
80
20.7
3.25
1.87
21.5
3.50
1.80
22.3
3.80
1.72
47
60
18.9
3.70
1.50
19.3
3.91
1.45
19.7
4.10
1.41
70
18.3
3.27
1.64
18.8
3.46
1.59
19.3
3.67
1.54
80
17.6
2.90
1.78
18.2
3.09
1.73
18.8
3.28
1.68
40
60
17.3
3.47
1.46
17.9
3.66
1.43
18.4
3.86
1.40
70
16.9
3.05
1.62
17.5
3.24
1.58
18.0
3.45
1.53
80
16.4
2.70
1.78
17.0
2.88
1.73
17.6
3.09
1.67
30
60
15.0
3.10
1.42
15.5
3.22
1.41
16.0
3.37
1.39
70
14.7
2.74
1.57
15.1
2.86
1.55
15.6
3.01
1.52
80
14.3
2.44
1.72
14.8
2.56
1.69
15.2
2.70
1.65
17
60
10.8
2.40
1.32
11.8
2.61
1.33
12.9
2.79
1.35
70
11.2
2.23
1.47
11.9
2.37
1.47
12.6
2.51
1.47
80
11.6
2.08
1.63
11.9
2.17
1.61
12.3
2.25
1.60
10
60
10.5
2.33
1.32
10.9
2.39
1.33
11.20
2.47
1.33
70
10.3
2.06
1.46
10.6
2.13
1.46
11.0
2.21
1.45
80
10.0
1.83
1.60
10.4
1.91
1.59
10.7
2.00
1.57
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Yellow shaded cells are AHRI High Heating conditions.
Orange shaded cells are AHRI Low Heating conditions.
COIL MULTIPLIERS- 1.5 TON
Air Handler
Coil
MBH
COP
KW
–
CF/CM/CU18A
0.93
1.01
0.92
–
CF/CM/CU18B
0.93
1.01
0.92
–
CF/CM/CU24A
0.93
1.01
0.92
–
CF/CM/CU24B
0.93
1.01
0.92
–
CF/CM/CU24C
0.93
1.01
0.92
AE24BX21
–
0.96
1.10
0.87
AP18BX21
–
0.93
1.01
0.92
AVC18BX21
–
0.96
1.09
0.88
AVC24BX21
–
1.00
1.10
0.91
ME08BN21
CF/CM18B
0.96
1.10
0.87
ME08BN21
CF/CM24B
0.96
1.11
0.86
ME12BN21
CF/CM18B
0.96
1.03
0.93
ME12BN21
CF/CM24B
0.96
1.04
0.92
MVC08BN21
CF/CM18B
0.97
1.09
0.88
MVC08BN21
CF/CM24B
0.96
1.12
0.85