background image

363658-CTG-G-0613

4

Johnson Controls Unitary Products

ACCESSORIES

Propane (LP) Conversion Kit - 

This accessory conversion kit

may be used to convert natural gas units for propane (LP) oper-
ation.

1NP0347 - All Models except 130,000 BTU input
1NP0501 - 130,000 BTU input only

Side Return Filter Racks - 

1SR0200 - All Models
1SR0302 - All Models
1SF0101 - All Models

Bottom Return Filter Racks - 

1BR05xx series are galvanized

steel filter racks. 1BR06xx are pre-painted steel filter racks to
match the appearance of the furnace cabinet.

1BR0514 or 1BR0614 - For 14-1/2” cabinets
1BR0517 or 1BR0617 - For 17-1/2” cabinets
1BR0521 or 1BR0621 - For 21” cabinets
1BR0524 or 1BR0624 - For 24-1/2” cabinets

Masonry Chimney Kits - 

For installations where these fur-

naces are vented using existing or new lined masonry chim-
neys.

1CK0603
1CK0604

Combustible Floor Base Kit -

 For installation of these fur-

naces in downflow applications directly onto combustible floor-
ing material, These kits are required to prevent potential
overheating situations. These kits are also required in any appli-
cations where the furnace in installed in a downflow configura-
tion without an evaporator coil, where the combustible floor
base kit provides access for combustible airflow.

1CB0514 - For 14-1/2” cabinets
1CB0517 - For 17-1/2” cabinets
1CB0521 - For 21” cabinets
1CB0524 - For 24-1/2” cabinets

High Altitude Pressure Switches -

 For installation where the

altitude is less than 8,000 feet it is not required that the pres-
sure switch be changed. For altitudes above 8,000 feet, see kits
below.

1PS3301 - 040, 060, 080, 120
1PS3302 - 100, 130

Thermostats - 

Compatible thermostat controls are available

through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.

Summary of Contents for TG8S

Page 1: ...ional Fuel Gas Code FEATURES Easily applied in upflow horizontal left or right or downflow installation with minimal conversion necessary Compact easy to install ideal height 33 tall cabinet Blower off delay for cooling SEER improvement Easy access to controls to connect power control wiring Built in high level self diagnostics with fault code displays standard on integrated control module for rel...

Page 2: ... 8 L S100B12MP11 1200 B 17 1 2 16 3 8 11 8 108 TG 8 L S100C16MP11 1600 C 21 19 7 8 13 6 118 TG 8 L S100C20MP11 2000 C 21 19 7 8 13 6 122 TG 8 L S120C16MP11 1600 C 21 19 7 8 15 8 123 TG 8 L S120C20MP11 2000 C 21 19 7 8 15 8 129 TG 8 L S130D20MP11 2000 D 24 1 2 23 3 8 17 5 135 Ratings Physical Electrical Data Models Input Output AFUE Air Temp Rise Max Outlet Air Temp Blower Blower Size Max Over Curr...

Page 3: ...e return with a transition to allow use of a 20x25 filter Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer s rec ommendation and a transition is used to allow use on a 20x25 filter NOTICE Recommended Filter Sizes CFM Cabinet Size Side in Bottom in 800 A 16 x 25 14 x 25 1000 A 16 x 25 14 x 25 1200 A 16 x 25 14 x 25 1200 B 16 x 25 16 x ...

Page 4: ... 1CK0603 1CK0604 Combustible Floor Base Kit For installation of these fur naces in downflow applications directly onto combustible floor ing material These kits are required to prevent potential overheating situations These kits are also required in any appli cations where the furnace in installed in a downflow configura tion without an evaporator coil where the combustible floor base kit provides...

Page 5: ...0 2448 2339 2224 2111 1974 1831 Medium High 2234 2233 2147 2092 2042 1974 1907 1820 1705 1575 Medium Low 1722 1716 1690 1681 1603 1553 1489 1426 1335 1241 Low 1396 1375 1348 1325 1263 1200 1150 1120 1052 965 TG 8 L S100B12MP11 High 1314 1318 1292 1265 1223 1177 1119 1051 971 890 Medium High 1010 1004 1003 995 992 956 914 857 798 721 Medium Low 812 805 796 786 777 754 727 685 626 560 Low 661 659 64...

Page 6: ...1035 Medium 1294 1297 1271 1238 1187 1120 1083 1028 979 851 Low 1126 1115 1095 1049 1027 996 957 929 840 742 TG 8 L S080C22MP11 High 2972 2863 2769 2671 2571 2465 2352 2227 2095 1950 Medium High 2173 2146 2103 2082 2036 1966 1904 1827 1738 1621 Medium Low 1670 1667 1647 1618 1585 1549 1492 1408 1350 1238 Low 1371 1339 1317 1284 1259 1199 1147 1085 1024 928 TG 8 L S100B12MP11 High 1258 1278 1283 12...