CAUTION

• The inverter is designed to operate from a 12-volt power source only. The unit 

will not operate from a 6-volt battery or a 24-volt battery. 

Do not attempt 

to connect the inverter to any other power nominal output voltage 

other than 12 volts or damage to the unit may occur. Any damage 

to the unit that occurs from operating the inverter from any power 

source greater than or less than 12 volts will automatically void the 

warranty. 

• Do not attempt to extend or otherwise modify the 12-volt power cord attached 

to the inverter.

• 110/120 volts can inflict serious injury, damage or death. Improper use of the 

inverter may result in property damage, personal injury or loss of life.

Connecting the Inverter

The inverter is equipped with a fused 12-volt power cord for connection to the 

power source.
1. Make sure that the ON/OFF power switch located on the front panel of 

inverter is in the OFF(O) position.

2. Connect the inverter to the power source by inserting the 12-volt power cord 

firmly into the cigarette lighter socket of your vehicle or other 12-volt DC 

power source.

3. Turn the inverter power switch to the ON(-) position. The GREEN LED Indicator 

Light should illuminate to confirm that power is running to the inverter.

4. Make sure that the device you intend to operate is turned OFF. Plug the cord 

from the equipment into the AC outlet located on the front panel of the 

inverter.

5. Turn the inverter power switch to the ON(-) position; then turn the  

equipment ON.

Notes

• The audible alarm may make a momentary “chirp” when the inverter is turned 

ON (-) or OFF(O). This same alarm may also sound when the inverter is being 

connected to or disconnected from the 12-volt power source. This is normal.

• If the GREEN LED Indicator Light blinks when you first turn the inverter ON(-), 

this may indicate an interruption of the power supply. Simply turn the inverter 

OFF(O) and remove the 12-volt power cord from the cigarette lighter socket (or 

other 12-volt power source). Firmly re-insert the 12-volt power cord, then turn 

the inverter ON(-) again. If this does not fix the problem, try using a different 

12-volt power source or check the cigarette lighter fuse.

3

Source of Power

Most automobile and marine batteries will provide an ample power supply to 

the inverter for 30 to 60 minutes even when the engine is turned off. Actual time 

may vary depending on the age and condition of the battery and the power 

demand being placed on it by the equipment being operated.
If you decide to use the inverter while the engine is off, we recommend that 

you start the engine every 30 to 60 minutes and let it run for approximately 10 

minutes to recharge the battery. It is also recommended that the device plugged 

into the inverter be turned OFF before starting the vehicle engine.
Although it is not necessary to disconnect the inverter when starting the vehicle 

engine, it may momentarily cease to operate as the battery voltage decreases. 

When the inverter is not supplying power, it draws very low amperage from the 

battery. It is recommend that the inverter always be disconnected when not in 

use.

Blown Automotive Fuses

Depending on the make and model of your automobile, running the power 

inverter near full capacity from your cigarette lighter socket may result in a 

blown automotive cigarette lighter fuse. This fuse will need to be replaced with 

the same type and size fuse. A blown automotive cigarette lighter fuse will not 

cause damage to your vehicle wiring.

Blown Inverter Fuses

Your power inverter is equipped with a 25-amp spade type fuse. With 

reasonable care, it should not be necessary to replace this fuse. In general, 

most blown fuses are the result of reverse polarity hook up of the inverter to a 

12-volt power source (positive to negative and/ or negative to positive). If the 

fuse happens to blow, disconnect the appliance or equipment from the inverter 

immediately. Find the source of the problem, repair it and then install a new 

fuse of the same type and size located on the rear panel of the inverter.

Note 

Always disconnect the power inverter from the 12-volt power source and make 

sure the inverter is turned OFF before replacing the fuse.

Safety and Usage Precautions

• For best operating results, place the inverter on a flat surface.
• Keep the inverter dry. Do not expose the inverter to rain or moisture.
• DO NOT operate the inverter if you, the inverter, the device being operated, or 

any surface that may come into contact with the inverter are wet. Water and 

other liquids can conduct electricity, which may lead to serious injury or death.

4

PMP200XL_122205M.indd   8-9

12/22/05   9:09:47 AM

Summary of Contents for PMP200XL

Page 1: ...ent After 30 days but before the end of the 2 year warranty period you may return the product to the following address Team Products International Attn Customer Service Returns 35 A Continental Drive Wayne NJ 07470 We suggest that you retain your original packing material in the event you need to ship your product When sending your product include your name address phone number proof of date of pu...

Page 2: ...PMP200XL Models Owner s Manual PMP200XL_122205M indd 4 5 12 22 05 9 09 47 AM ...

Page 3: ...o 110 120 volt alternating current AC Depending on the model and its rated capacity the inverters draw power either from standard 12 volt automobile and marine batteries or from portable high power 12 volt sources Getting Started When you turn on an appliance or a tool that operates using a motor or a tube such as a television it requires an initial surge of power to start up This surge of power i...

Page 4: ...e and marine batteries will provide an ample power supply to the inverter for 30 to 60 minutes even when the engine is turned off Actual time may vary depending on the age and condition of the battery and the power demand being placed on it by the equipment being operated If you decide to use the inverter while the engine is off we recommend that you start the engine every 30 to 60 minutes and let...

Page 5: ... Audio Suggestions Although all COLEMAN inverters are shielded and filtered to minimize signal interference some interference with your television picture may be unavoidable especially with weak signals However here are some suggestions that may improve reception Make sure the television antenna produces a clear signal under normal operating conditions at home plugged into a standard 110 120 volt ...

Page 6: ...n the event of a continuous audible alarm or an automatic shut down of the unit turn the inverter OFF immediately Do not turn the inverter ON again until the source of the problem has been identified and corrected To avoid battery drain always disconnect the inverter when not in use Do not expose the inverter to rain or moisture Avoid placing the inverter near sources of heat or in direct sunlight...

Page 7: ...22 Troubleshooting PROBLEM Low or No Output Voltage PROBLEM Red LED On 9 Reason Solution Electrical interference from Add an AC interference filter on the inverter to theTV power cord Refer toTV and audio section of this manual Reason Solution TV does not turn on Try turning the inverter ON OFF ON ContactTV manufacturer for start up surge and power consumption A larger inverter may be required PRO...

Page 8: ...PMP200XL Models Owner s Manual PMP200XL_122205M indd 16 17 12 22 05 9 09 51 AM ...

Reviews: