background image

Johnson Controls Unitary Products

7

5154297-CTG-C-0216

ACCESSORIES

Refer to Price Manual for specific model numbers where not
shown.

TXV Kits

 - “Flex-coils” are shipped without a factory installed

metering device. For added flexibility, an R-22 or R-410A TXV
or piston must be field installed to meet your refrigerant choice.
All kits are chatleff style and require no brazing to install.

Breaker Moisture Seal Accessory - A clear circuit breaker
moisture barrier seals the breakers from humidity and dust. The
flexibility of the clear cover allows circuit breakers to be turned
ON or OFF without removing the cover. The cover firmly
attaches to the access panel around the circuit breakers with
the use of double backed adhesive tape. To ensure that
moisture or dust does not contaminate circuit breakers, an S1-
02435672000, Circuit Breaker, Cover Seal may be ordered.

Bottom Rack Filter Kit -

 The filter frame accessory allows

installation of an external air handler filter in an upflow
application, a downflow application, or a horizontal application
(refer to the following illustration/table for Filter Rack
Dimensions).

Thermostat -

 Compatible thermostat controls are available

through accessory sourcing. For optimum performance, these
outdoor units are fully compatible with our Coleman touch
screen thermostat with proprietary (patent-pending) hexagon
interface. For more information, see the thermostat section of
the Product Equipment Catalog.

FILTER RACK DIMENSIONS

Galvanized 

Models

A

B

C

D

E

Filer Size

1BR01117

17.50 21.56 4.00 18.63 14.25

16 x 20 x 1 or 2

1BR01121

21.00 21.56 4.00 18.63 17.75

20 x 20 x 1 or 2

1BR01124

24.50 21.56 4.00 18.63 21.25

20 x 24 x 1 or 2

Note: 

Filters - Not supplied with kit.

A

C

B

D

E

A0146-003

SIDE

TRACKS

11/16

Summary of Contents for MP12BN11

Page 1: ...ER AND CM COIL FEATURES RC2 Rigid Case Construction interior endoskeleton for structural support smooth side and locks in insulation Powder painted G30 galvanized steel case provide a coated edge that...

Page 2: ...IONS 6 TYPICAL THERMOSTAT CONNECTION 6 ACCESSORIES 7 FILTER RACK DIMENSIONS 7 AIR FLOW DATA CFM 8 WIRING DIAGRAM 9NOMENCLATURE PRODUCT TYPE M M Modular Blower POSITION MOTOR TYPE P P Multi PSC E Multi...

Page 3: ...2 23 1 2 Models Dimensions 1 Height Width Opening Widths Refrigerant Connections 2 Line Size A B C D Liquid Vapor CM18A 19 1 2 14 1 2 13 1 2 13 1 2 3 8 3 4 CM18B 19 17 1 2 16 1 2 16 1 2 CM24A 19 1 2 1...

Page 4: ...37 8 30 1 21 5 16 2 CM30D 1000 85 72 75 3 67 8 56 8 47 1 80 67 62 6 54 6 44 2 34 5 75 62 50 2 41 3 32 0 22 9 70 57 37 8 30 1 21 5 16 2 CM36B 1000 85 72 82 1 73 7 64 1 54 4 80 67 68 6 60 1 50 5 39 5 75...

Page 5: ...dels Rated CFM2 Entering Air Dry Wet Bulb F MBH Evap Temp and Corresponding R 410A Pressure F PSIG 35 107 9 40 118 9 45 130 7 50 143 3 PHYSICAL ELECTRICAL DATA COOLING ONLY Models MP08B MP12B MP14D MP...

Page 6: ...TRANSFORMER FACTORY WIRED TO FAN MOTOR RELAY TERMINAL ON CONTROL BOARD PUR PUR HIGH MED LOW GND 115 VOLT BLOWER MOTOR CAP BRN BLK A0460 001 PSC STANDARD MOTOR FACTORY WIRED TO TRANSFORMER FACTORY WIRE...

Page 7: ...ot contaminate circuit breakers an S1 02435672000 Circuit Breaker Cover Seal may be ordered Bottom Rack Filter Kit The filter frame accessory allows installation of an external air handler filter in a...

Page 8: ...83 2033 1960 1894 1820 1720 1459 Medium 1690 1662 1623 1587 1534 1460 1233 Low 1399 1393 1370 1338 1269 1159 1073 MP16C CM36C High 1850 1785 1705 1625 1541 1373 1242 Medium 1693 1642 1574 1499 1378 12...