036-21326-001-C-0202
Unitary Products Group
11
TABLE 12: 15 TON CAPACITY TABLE - 85º AND 95ºF
15 Ton Capacity Tables
HL180 Matched with LL180
AIR ON EVAPORATOR
OUTDOOR AMBIENT TEMPERATURE (F):
85
º
CFM
W.B.
GROSS
INPUT
GROSS SENSIBLE CAPACITY (MBh)
TEMP
CAP.
POWER
(RETURN AIR DRY BULB TEMP.- (F))
(F)
(MBh)
(kW)
86
83
80
77
74
71
68
4500
72
197.8
15.23
117.3
104.5
91.6
78.8
66.0
#N/A
#N/A
67
183.8
14.90
144.8
131.9
119.1
106.3
93.4
80.6
67.8
62
170.5
14.50
168.2
155.4
142.6
129.8
116.9
104.1
91.3
57
173.8
14.43
173.8
171.0
158.2
145.3
132.5
119.7
106.9
5250
72
204.1
15.34
129.7
114.5
99.4
84.2
69.0
#N/A
#N/A
67
189.6
15.01
159.4
144.3
129.1
114.0
98.8
83.6
68.5
62
175.9
14.60
174.8
168.3
154.6
139.4
124.3
109.1
93.9
57
179.3
14.53
179.3
177.9
171.5
156.3
141.2
126.0
110.8
6000
72
210.3
15.44
142.1
124.6
107.1
89.6
72.1
#N/A
#N/A
67
195.4
15.12
174.1
156.6
139.1
121.6
104.1
86.6
69.2
62
181.3
14.70
181.3
181.3
166.6
149.1
131.6
114.1
96.6
57
184.8
14.64
184.8
184.8
184.8
167.3
149.8
132.3
114.8
6750
72
213.6
15.54
152.3
132.4
112.5
92.6
72.6
#N/A
#N/A
67
198.4
15.21
186.0
166.1
146.2
126.3
106.3
86.4
66.5
62
184.0
14.80
184.0
184.0
175.0
155.1
135.2
115.3
95.3
57
187.6
14.73
187.6
187.6
187.6
167.7
147.8
127.8
107.9
7500
72
216.8
15.64
162.6
140.3
117.9
95.6
73.2
#N/A
#N/A
67
201.4
15.31
198.0
175.6
153.3
130.9
108.5
86.2
63.8
62
186.8
14.89
186.8
186.8
183.5
161.1
138.8
116.4
94.1
57
190.5
14.82
190.5
190.5
190.5
168.1
145.7
123.4
101.0
Indicates Nominal Capacity Rating Point.
INPUT POWER INCLUDES THE CONDENSER AND COMPRESSOR MOTORS BUT NOT THE INDOOR BLOWER MOTOR
15 Ton Capacity Tables
HL180 Matched with LL180
AIR ON EVAPORATOR
OUTDOOR AMBIENT TEMPERATURE (F):
95
º
CFM
W.B.
GROSS
INPUT
GROSS SENSIBLE CAPACITY (MBh)
TEMP
CAP.
POWER
(RETURN AIR DRY BULB TEMP.- (F)
(F)
(MBh)
(kW)
86
83
80
77
74
71
68
4500
72
190.9
16.89
114.1
101.3
88.5
75.7
62.8
#N/A
#N/A
67
176.8
16.51
142.2
129.4
116.5
103.7
90.9
78.0
65.2
62
162.8
16.18
162.8
153.2
140.3
127.5
114.7
101.8
89.0
57
163.2
16.11
163.2
158.1
145.2
132.4
119.6
106.7
93.9
5250
72
196.2
16.99
126.2
111.0
95.8
80.7
65.5
#N/A
#N/A
67
181.7
16.61
156.5
141.4
126.2
111.0
95.9
80.7
65.6
62
167.4
16.27
167.4
162.5
152.0
136.8
121.6
106.5
91.3
57
167.7
16.20
167.7
165.2
157.3
142.1
127.0
111.8
96.6
6000
72
201.5
17.09
138.2
120.7
103.2
85.7
68.2
#N/A
#N/A
67
186.6
16.71
170.9
153.4
135.9
118.4
100.9
83.4
65.9
62
171.9
16.37
171.9
171.9
163.6
146.1
128.6
111.1
93.6
57
172.3
16.30
172.3
172.3
169.3
151.8
134.4
116.9
99.4
6750
72
205.1
17.17
148.4
128.5
108.6
88.6
68.7
#N/A
#N/A
67
190.0
16.79
182.1
162.9
143.0
123.1
103.1
83.2
63.3
62
175.0
16.45
175.0
175.0
170.9
150.9
131.0
111.1
91.2
57
175.4
16.37
175.4
175.4
173.9
154.0
134.1
114.2
94.2
7500
72
208.8
17.25
158.7
136.3
114.0
91.6
69.2
#N/A
#N/A
67
193.4
16.86
193.4
172.4
150.1
127.7
105.4
83.0
60.7
62
178.1
16.52
178.1
178.1
178.1
155.7
133.4
111.0
88.7
57
178.5
16.45
178.5
178.5
178.5
156.2
133.8
111.4
89.1
Indicates Nominal Capacity Rating Point.
INPUT POWER INCLUDES THE CONDENSER AND COMPRESSOR MOTORS BUT NOT THE INDOOR BLOWER MOTOR