background image

Subject to change without notice. Printed in U.S.A.

260614-CTG-C-0407

Copyright

 ©

 by York International Corp. 2007. All rights reserved.

Supersedes: 260614-CTG-B-0806

Unitary

5005

Norman

Products

York

OK

Group

Drive

73069

NOTES

Summary of Contents for FC9V Series

Page 1: ...as valve Two stage inducer operation Variable speed ECM blower operation Provides increased comfort level very quiet unit opera tion Adjustable delay timer allows two stage operation with sin gle stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code dis...

Page 2: ...NS Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in FC9V040A12UP11 1200 A 14 1 2 13 1 2 11 1 2 6 1 4 FC9V060B12UP12 1200 B 17 1 2 16 1 4 14 1 2 8 1 2 FC9V080B12UP11 1200 B 17 1 2 16 1 4 14 1 2 8 1 2 FC9V080C16UP12 1600 C 21 19 3 4 18 8 7 8 FC9V100C20UP12 2000 C 21 19 3 4 18 8 7 8 FC9V120D20UP12 2000 D 24 1 2 23 1 4 21 1 2 10 5 8 ELECTRICAL AND PERFORMANCE DATA Models Input Hig...

Page 3: ...0 920 C A 1250 790 1290 790 D A 1310 810 1360 840 C C 1090 690 1140 690 D C HIGH LOW HEAT CFM FC9V040A12UP11 FC9V060B12UP12 Jumper Settings High Low High Low HEAT Tap ADJ Tap 1045 740 1110 710 A Any 905 645 960 640 B Any 825 595 870 600 C Any 765 590 830 570 D Any FC9V080B12UP11 FC9V080C16UP12 Jumper Settings High Low High Low HEAT Tap ADJ Tap 1330 880 1490 990 A Any 1180 810 1350 900 B Any 1100 7...

Page 4: ...on the number of return air openings or return air opening size and add to the ESP from Step 3 to determine the total system static 5 If total system static matches a ESP value in the airflow table i e 0 20 0 60 etc the system airflow corre sponds to the intersection of the ESP column and Model Blower Speed row FILTER SIZES Input Output BTU H CFM Cabinet Size Side Return Filter in Bottom Return Fi...

Page 5: ... O Reversing Valve Energized in Cool TWO STAGE AIR CONDITIONING Comfort Alert Interface HUM Dehumidification Open on Humidity Rise C 24 Volt Common C 24 Volt Common R 24 Volt Hot W2 Second Stage Heat G Fan Y2 Second Stage Cool E W1 First Stage Heat RC 24 Volt Hot Cool XFMR Y1 First Stage Cool R 24 Volt Hot Y Y2 Single Second Stage Cool Y2 Second Stage Cool Y First Stage Cool Y2 Second Stage Cool W...

Page 6: ...elay on furnace to OFF HM Humidistat BSG Bonnet Sensor Bonnet Sensor Optional BS Bonnet Sensor AUX Auxiliary Heat E W1 First Stage Auxiliary Heat E W1 First Stage Auxiliary Heat W Auxiliary Heat Y2 Second Stage Heat Cool DHM Dehumidistat HUM Dehumidification Open on Humidity Rise Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y 2 O Reversing Valve Energized in Cool L...

Page 7: ...ts all cabinet sizes Attaches to side of furnace cabinet in side return applications Holds any 16x25x1 permanent or disposable filter SIDE RETURN FILTER RACK 1SR0302 All Models 1SR0200 All Models BOTTOM RETURN FILTER RACK 1BR0114 or 1BR0214 For 14 1 2 cabinets 1BR0117 or 1BR0217 For 17 1 2 cabinets 1BR0121 or 1BR0221 For 21 cabinets 1BR0124 or 1BR0224 For 24 1 2 cabinets HIGH ALTITUDE PRESSURE SWI...

Page 8: ...o change without notice Printed in U S A 260614 CTG C 0407 Copyright by York International Corp 2007 All rights reserved Supersedes 260614 CTG B 0806 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...