TABLE 1: Blower Performance CFM - Upflow (without filter) - Bottom Return

MODELS

Input / 

CFM

Speed

Two Stage Bottom Airflow Data (SCFM) 

Ext. Static Pressure (in. H2O) 

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 

(F,L)C8T060A12UH11

High 

1570 1490 1420 1340 1250 1180 1090  990  870  700 

Medium 

High  1410 1360 1310 1250 1190 1090 1020  920  810  650 

Medium 

Low  1200 

1180 

1150 

1100 

1050 990 920 830 700 580 

Low 

960 960 950 930 900 840 800 720 610 500 

(F,L)C8T080A12UH11

High 

1590 1520 1460 1380 1300 1240 1150 1050  930  800 

Medium 

High  1400 1360 1310 1260 1200 1140 1070  960  860  740 

Medium 

Low  1180 

1160 

1130 

1090 

1040 990 920 840 750 640 

Low 

940 940 940 920 880 840 790 710 630 530 

(F,L)C8T080B16UH11

High 

1850 1820 1790 1750 1690 1630 1570 1500 1430 1330 

Medium 

1470 1450 1440 1430 1390 1360 1310 1270 1220 1150 

Low 

1260 1260 1260 1260 1250 1200 1150  1110 1070 1010 

FC8T100B12UH11

High

1700 1620 1560 1480 1390 1300 1210 1110  970  820 

Medium 

High  1430 1400 1350 1300 1230 1160 1080  980  870  710 

Medium 

Low  1180 1170 1160 1130 1080 1030 1000  860  750  510 

Low 

950 950 930 920 880 840 790 720 620 530 

(F,L)C8T100C20UH11

High

2590 2500 2400 2280 2180 2080 1970 1840 1720 1560 

Medium 

High  2180 2120 2040 1980 1900 1810 1720 1600 1480 1320 

Medium 

Low  1750 1720 1680 1640 1580 1520 1440 1350 1220 1060 

Low 

1450 1420 1380 1330 1300 1240 1160 1070  970  860 

FC8T120C16UH11

High

2020 1930 1820 1730 1640 1540 1400 1250 1090  920 

Medium 

1750 1710 1650 1590 1490 1390 1290 1160 1010  810 

Low 

1540 1500 1460 1410 1350 1260 1180 1060  910  750 

FC8T120C16UH11

 

High 

2500 2400 2320 2220 2110 2000 1870 1750 1610 1450 

Medium 

High  2130 2070 1990 1920 1840 1760 1660 1570 1460 1320 

Medium 

Low  1700 1680 1650 1620 1560 1500 1410 1320 1210 1070 

Low 

1420 1390 1360 1330 1290 1240 1150 1060  950  840 

Summary of Contents for Echelon FC8T

Page 1: ... year heat exchanger warranty on commercial applica tions 5 year limited parts warranty FEATURES Two stage heating operation includes Two stage gas valve Two stage inducer operation Provides increased comfort level very quiet unit oper ation Adjustable delay timer allows two stage operation with single stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SE...

Page 2: ...1 8 10 1 8 F L C8T080B16UH11 64 48 1600 B 17 1 2 16 1 4 13 1 8 11 5 8 FC8T100B12UH11 80 53 1200 B 17 1 2 16 1 4 13 1 8 11 5 8 F L C8T100C20UH11 80 53 2000 C 21 19 3 4 16 5 8 13 3 8 FC8T120C16UH11 96 64 1600 C 21 19 3 4 16 5 8 13 3 8 F L C8T120C20UH11 96 64 2000 C 21 19 3 4 16 5 8 13 3 8 HORIZONTAL VENTING MUST USE FIELDS CONTROL MODELS SWG 4Y OR TJERENLAND MODEL GPAK JT FIELD SUPPLIED POWER VENTIN...

Page 3: ...14 1 2 80 0 25 55 165 F L C8T080A12UH11 64 48 1200 14 1 2 80 0 30 60 175 F L C8T080B16UH11 64 48 1600 17 1 2 80 0 25 55 160 FC8T100B12UH11 80 53 1200 17 1 2 80 0 25 55 170 F L C8T100C20UH11 80 53 2000 21 80 0 25 55 160 FC8T120C16UH11 96 64 1600 21 80 0 25 55 180 F L C8T120C20UH11 96 64 2000 21 80 0 25 55 170 Model Output Blower Blower Size Total Unit Max Over current Size awg 75 ft protect Min Wir...

Page 4: ...0 F L C8T080B16UH11 High 1850 1820 1790 1750 1690 1630 1570 1500 1430 1330 Medium 1470 1450 1440 1430 1390 1360 1310 1270 1220 1150 Low 1260 1260 1260 1260 1250 1200 1150 1110 1070 1010 FC8T100B12UH11 High 1700 1620 1560 1480 1390 1300 1210 1110 970 820 Medium High 1430 1400 1350 1300 1230 1160 1080 980 870 710 Medium Low 1180 1170 1160 1130 1080 1030 1000 860 750 510 Low 950 950 930 920 880 840 7...

Page 5: ...0 Low 1220 1230 1230 1230 1200 1190 1170 1160 1110 1050 FC8T100B12UH11 High 1780 1710 1640 1560 1490 1390 1290 1180 1030 820 Medium High 1430 1410 1370 1340 1280 1220 1140 1040 890 730 Medium Low 1140 1170 1150 1120 1080 1040 970 890 760 630 Low 920 940 950 940 920 890 850 770 660 560 F L C8T100C20UH11 High 2770 2670 2610 2540 2450 2340 2210 2070 1890 1730 Medium High 2120 2060 2030 2000 1950 1880...

Page 6: ...hat total system static is 0 58 w c To determine the system airflow complete the following steps Obtain the airflow values at 0 50 w c 125 Pa 0 60 w c 150 Pa ESP Airflow 0 50 2125 CFM 60 17 m3 min Airflow 0 60 2035 CFM 57 62 m3 min Subtract the airflow 0 50 w c 125 Pa from the airflow 0 60 w c 150 Pa to obtain airflow difference 2035 2125 90 CFM 2 55 m3 min Subtract the total system static from 0 ...

Page 7: ...WITCHES Used to convert units for operation at altitudes from 4 500 ft to 10 000 ft Input MBH Output MBH 2 000 Ft to 5 500 Ft 5 500 Ft to 0 000 Ft 40 32 1PS0301 1PS0301 60 48 1PS0301 1PS0301 80 64 1PS0302 1PS0302 100 80 1PS0312 1PS0311 115 92 1PS0312 1PS0311 130 104 1PS0312 1PS0311 FIELD INSTALLED ACCESSORIES ELECTRICAL MODEL NO DESCRIPTION USED WITH 2ET0770010124 THERMOSTAT Two stage Heat Cool de...

Page 8: ...e without notice Printed in U S A 036 21603 002 Rev A 1004 Copyright by York International Corp 2004 All rights reserved Supersedes 036 21603 001 Rev B 0904 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...