5545025-CTG-F-0820
Johnson Controls Ducted Systems
9
— = Not applicable.
MP Modular Air Handlers use Coil Only Ratings.
CC17B4821S
MVC14DN21
24.5
CF/CM/CU48D
1
850
38.5
25.8
16.50
23.60
2
1350
47.5
34.4
13.00
CC17B4821S
MVC16CN21
21.0
CF/CM/CU48C
1
950
39.0
27.0
16.00
23.50
2
1500
47.5
36.0
13.00
CC17B4821S
MVC16CN21
21.0
CF/CM/CU60C
1
950
39.0
27.2
16.00
23.46
2
1500
47.5
36.4
13.00
CC17B4821S
MVC20DN21
24.5
CF/CM/CU48D
1
950
39.0
27.0
16.50
23.83
2
1375
47.5
34.8
13.00
CC17B4821S
MVC20DN21
24.5
CF/CM/CU60D
1
1150
40.5
30.0
17.00
24.39
2
1775
47.5
38.0
13.25
CC17B4821S
MVC20DN21
24.5
CF/CM64D
1
1150
40.5
30.0
17.00
24.34
2
1775
47.5
38.5
13.25
CC17B6021S
AE60CX21
21.0
–
1
1450
46.7
35.6
15.00
20.75
2
1650
57.5
42.5
12.25
CC17B6021S
AE60DX21
24.5
–
1
1400
47.7
35.6
16.00
21.83
2
1750
59.0
44.0
12.50
CC17B6021S
AVC60CX21
21.0
–
1
1025
44.2
30.1
15.00
20.94
2
1625
57.0
41.5
11.75
CC17B6021S
AVC60DX21
24.5
–
1
1050
45.2
30.9
16.00
21.83
2
1600
58.0
42.0
12.75
CC17B6021S
ME14DN21
24.5
CF/CM/CU60D
1
1400
46.7
34.8
15.00
21.03
2
1500
57.0
40.5
12.50
CC17B6021S
ME14DN21
24.5
CF/CM64D
1
1375
47.2
35.2
15.50
21.32
2
1475
58.0
41.0
12.50
CC17B6021S
ME16CN21
21.0
CF/CM/CU60C
1
1350
46.2
34.2
15.00
20.80
2
1500
57.0
40.5
12.50
CC17B6021S
ME20DN21
24.5
CF/CM/CU60D
1
1325
46.7
34.2
16.00
22.07
2
1700
58.0
43.0
12.75
CC17B6021S
ME20DN21
24.5
CF/CM64D
1
1325
47.2
34.6
16.00
22.40
2
1675
59.0
43.5
13.00
CC17B6021S
MVC14DN21
24.5
CF/CM/CU60D
1
1000
44.2
29.9
16.00
21.69
2
1450
57.0
40.0
12.75
CC17B6021S
MVC14DN21
24.5
CF/CM64D
1
1000
44.7
30.1
16.00
22.02
2
1450
58.0
40.5
13.00
CC17B6021S
MVC16CN21
21.0
CF/CM/CU60C
1
1075
44.7
31.1
15.50
21.69
2
1725
58.0
43.5
12.25
CC17B6021S
MVC20DN21
24.5
CF/CM/CU60D
1
1150
45.7
32.0
16.00
22.30
2
1775
58.5
44.0
12.75
CC17B6021S
MVC20DN21
24.5
CF/CM64D
1
1150
46.2
32.4
16.00
22.54
2
1775
59.5
44.5
12.75
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those
conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total
electric power input in watt-hours during the same period.
1. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
SYSTEM CAPACITY -
With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
STAGE
RATED
CFM
COOLING
MODEL
WIDTH
NET MBH
SEER
EER
TOTAL
SENS.