CONTENTS 

 

 
1. 

INTRODUCTION    ------------------------------------------------------------- 

 PG. 

 
 
2. 

SELECTING 

LOCATION   ------------------------------------------------------------- 

 PG. 

 
 
3. 

MINIMUM 

CLEARANCES 

  ------------------------------------------------------------- 

 PG. 

 
 
4. 

FRAMING 

AND 

INSTALLING 

  ------------------------------------------------------------- 

 PG. 

 
 
5. 

 

HEARTH 

EXTENSION 

   ------------------------------------------------------------- 

 PG. 

 
 
6. 

OUTSIDE AIR KIT INSTALLATION 

 

-------------------------------------------------------------   

PG. 4 

 
 
7. 

FAN 

KIT 

ASSEMBLY 

   ------------------------------------------------------------- 

 PG. 

 
 
8. 

CHIMNEY 

PIPE 

    ------------------------------------------------------------- 

 PG. 

4-5 

 
 
9. 

FIRESTOP THIMBLE AND SPACERS           

-------------------------------------------------------------   

PG. 5-6 

 
 
10. 

FLASHING AND TERMINATION 

 

-------------------------------------------------------------   

PG. 7 

 
 
11. 

FINISHING 

YOUR 

FIREPLACE 

  ------------------------------------------------------------- 

 PG. 

 
 
12. 

MANTEL 

    ------------------------------------------------------------- 

 PG. 

 
 
13. 

GLASS 

DOORS 

    ------------------------------------------------------------- 

 PG. 

 
 
14. 

GAS 

LINE 

INSTALLATIONS 

  ------------------------------------------------------------- 

 PG. 

 
 
15. 

DAMPER 

OPERATION 

   ------------------------------------------------------------- 

 PG. 

10 

 

 
 
16.  

TECHNICAL SERVICE 

   ------------------------------------------------------------- 

 PG. 

10 

 
 
17. 

ILLUSTRATED PARTS                                

-------------------------------------------------------------             PG.11-11a 

 
 
18. 

REPLACEMENT AND TECHNICAL PARTS 

-------------------------------------------------------------                PG.12 

 
 
19. 

PART NUMBER REFERENCE TABLE       

-------------------------------------------------------------                PG.12a 

 

Summary of Contents for C36MW

Page 1: ...pproved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA hood must be installed when using a vent free gas log heater see...

Page 2: ...T INSTALLATION PG 4 7 FAN KIT ASSEMBLY PG 4 8 CHIMNEY PIPE PG 4 5 9 FIRESTOP THIMBLE AND SPACERS PG 5 6 10 FLASHING AND TERMINATION PG 7 11 FINISHING YOUR FIREPLACE PG 8 12 MANTEL PG 8 13 GLASS DOORS...

Page 3: ...rs 0 minimum Mantel Clearances see page 8 Mantels Chimney Outer Pipe Surfaces 1 minimum MINIMUM MAXIMUM CHIMNEY HEIGHT The minimum height of the chimney measured from the base of the fireplace to the...

Page 4: ...rotector should be made of galvanized sheet metal 28 gage minimum to prevent corrosion STEP 6 Secure the fireplace to the floor using tie down straps see figure 3 to prevent shifting HEARTH EXTENSION...

Page 5: ...lide power source wiring through the strain relief opening and electrical cover plate and make all the necessary connections iv Slide all wiring connections in the electrical housing as shown in figur...

Page 6: ...c space of a manufactured home To install the thimble assembly determine the distance between the ceiling joist and the roof framing Attach the adjustable thimble to the firestop spacer so that the as...

Page 7: ...n in figure 13 PENETRATING THE ROOF To maintain a 1 inch clearance to the pipe on a roof with a pitch a rectangular opening must be cut STEP 1 Determine the center point through which the pipe will pe...

Page 8: ...ly waterproof caulk around the perimeter of the collar to provide a proper seal Note Storm collar is required but can be installed after the home is sited TERMINATIONS SPARK ARRESTOR The fireplace sys...

Page 9: ...L A mantel may be installed if desired see figure 20 Woodwork such as wood trims mantels or any other combustible material projecting from the front face must not be placed within 9 inches of the fire...

Page 10: ...out indentation must be firmly tapped with any solid object until it is released Remove fragmented portions of refractory see figure 22 STEP 2 Remove gas line cover plate on either side of fireplace a...

Page 11: ...ch in and push the handle back into the keyhole slot then pull down and forward to lock it in place see figure 25 FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER TO...

Page 12: ...11 For more information visit www desatech com ILLUSTRATED PARTS...

Page 13: ...MENT SIDE DAMPER 1 46 11412 COTTER PIN 1 1 2 x 1 16 2 15 108872 01 WELDMENT FRONT FACE 1 47 14607 SWITCH ROCKER 1 16 106948 01 DEFLECTOR AIR 1 48 14608 PLUG MALE POLARIZED 1 4 1 17 21198 PLATE BLOWER...

Page 14: ...24 8DM 24 Double Wall Pipe 1 0 18 8DM 18 Double Wall Pipe 0 2 FST A Adjustable Firestop Thimble 1 1 V6F 8DM Roof Flashing 1 1 VSC1 8DM Storm Collar 1 1 RTL 8DM Round Cap Termination 1 1 VENT KITS USE...

Page 15: ...DM 36 8DM DOUBLE WALL PIPE 36 SECTION 9736A1236 36 8DM 48 8DM DOUBLE WALL PIPE 48 SECTION 9736A1248 48 8DM V6F 8DM ROOF FLASHING 0 6 12 PITCH 9736 5241 V6F 8DM V12F 8DM ROOF FLASHING 6 12 12 12 PITCH...