Problem

Possible Cause

Solution

Pilot won’t light

Cylinder valve is closed

Open valve

Blockage in orifice or pilot tube

Clean or replace orifice or pilot tube

Air in gas line

Pilot may take 1-2 minutes to light after a propane bottle
has been connected

Low gas pressure with Cylinder Valve

Cylinder is empty. Replace cylinder

fully open

Igniter fails

Use match to light pilot. Obtain new igniter and
replace

Heater control knob not fully 

Depress heater control knob firmly in light position

depressed in pilot position when

when lighting pilot

lighting pilot 

No spark at burner electrode

Use match to light pilot. If wire to electrode is
damaged - replace with new wire and/or carbon 
across spark gap

Pilot won’t stay lit

Dirt built up around pilot

Clean dirt from around pilot

Connection between gas valve and

Tighten connection and perform leak check

pilot assembly is loose 

Thermocouple is not operating 

Tighten all thermocouple connections. Replace 

correctly

if faulty

Burner won’t light

Gas pressure is low

Turn Cylinder valve OFF and replace cylinder

Blockage in orifice

Clear blockage

Control knob is not in ON position

Turn control knob to ON

Light won’t light

Gas pressure is low

Turn Cylinder valve OFF and replace cylinder

Blockage in orifice

Clear blockage

Control knob is not in ON position

Turn control knob to ON

Igniter fails

Use match to light pilot. Obtain new igniter and
replace

Burner flame is low

Gas pressure is low

Turn Cylinder valve OFF and replace cylinder

Outdoor temperature is less than 40° F

Use a full cylinder

and tank is less than 1/4 full

Supply hose is bent or kinked

Straighten hose

Control knob fully ON

Check burner and orifices for blockage

Carbon build-up

Dirt or film on reflector and burner screen

Remove blockage from burner screen holes and clean
burner screen inside and outside

Thick black smoke from

Blockage in burner or in light gas passages

Remove blockage and clean burner inside and outside

burner or light

Mantles light but dim        

Faulty Regulator (First insure cylinder

Replace regulator

out when heater is

valve is fully open and that cylinder is

turned on.

not empty)

Pilot lights but Heater      

Faulty Regulator (First insure cylinder

Replace regulator

flame is “lazy” or has

valve is fully open and that cylinder is

low output.

not empty)

13

Service

• Repair to gas passages and associated components should be done only by a qualified service person.
• Owner repair & service should be limited and performed only to the 

following:
- Mantle replacement
- Glass replacement
- Reflector replacement

NOTE: Do not operate
heater below 0° F.

Troubleshooting

Summary of Contents for 5040B740

Page 1: ...www coleman com IMPORTANT Read this manual carefully before assembling using or servicing this heater Keep this manual for future reference If you have questions about assembly operation servicing or repair of this heater please call Coleman at 1 800 835 3278 or TDD 316 832 8707 In Canada call 1 800 387 6161 1AS 9 96 CSA International Requirement 5 90 U S ...

Page 2: ...n understand and follow the instructions should use or service this heater If you need assistance or heater information such as an instruction manual or labels contact the Coleman Co Inc DANGER General Safety Information If you smell gas 1 Shut off gas to the appliance 2 Extinguish open flame 3 If odor continues immediately call your gas supplier FOR YOUR SAFETY Do not store or use gasoline or oth...

Page 3: ...r where temperatures exceed 120 degrees F 49 C Propane is heavier than air and can accumulate in low places If you smell gas leave the area immediately Never install or remove propane tank while heater is lighted near flame pilot lights other ignition sources or while heater is hot to touch This heater is red hot during use and can ignite flammables too close to the burner Keep flammables at least...

Page 4: ... into base of Center Rear Support Bracket Attach Post Base to Cylinder Cover Pieces loosely with seven Large Screws 7 Required Large Screw 1 Required Large Screw 1 Required Large Screw Assemble three small screws loosely through Cover Pieces into Center Rear Support Bracket Attach one large screw loosely at base of Side Support Bracket Attach a Side Support Bracket loosely with Hex Nut at top Step...

Page 5: ...ighten all hex nuts Step 5 Attach three Support Brackets to Base with three large screws down ward through Support Brackets into the Base Attach one large screw loosely at base of the second Side Support Bracket Attach the second Side Support Bracket loosely with Hex Nut at top 1 Required Large Screw 2 Required Large Screw 3 Required Large Screw 1 Req d Hex Nut Attach Cylinder Cover Pieces to Base...

Page 6: ...ely attach clamp assembly to support tubes Insert table supports into the receptors located in the underside of the table frame NOTE Screws must be backed out of the support tubes Use those screws to attach the clamp in the next step Load table onto post by sliding table clamp over post and feed post through center hole of table Slide table to desired position Step 11 Tighten clamp so table is sec...

Page 7: ...pane vapor withdrawal supply system See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas ANSI NFPA 58 Your local library or fire department will have this book A minimum supply pressure of 11 0 W C is required for the purpose of input adjustment for propane gas The pressure regulator and hose assembly supplied with the appliance must be used The installation must confo...

Page 8: ...8 Step 15 continued Assembly continued Screw regulator onto hose Do not cross thread Tighten Securely Install tank Attach regulator to tank Complete attachment Install tank ...

Page 9: ...es appear at any connection there is a leak Turn Cylinder Valve OFF If leak is at Hose Regulator connection tighten connection and perform another leak test If you continue to see bubbles after several attempts contact 1 800 835 3278 for assistance If leak is at Regulator Cylinder Valve connection disconnect reconnect and perform another leak check If you continue to see bubbles after sev eral att...

Page 10: ... 2 feet from top Keep gasoline and other flammable liquids and vapors well away from heater The propane tank must always be stored outdoors in a well ventilated space Never store propane tank in an enclosed area house garage etc If heater is to be stored indoors disconnect the propane tank for outdoor storage CARBON MONOXIDE HAZARD For outdoor use only Never use inside house or other unventilated ...

Page 11: ...uld be closed and a waiting period of at least 5 minutes should pass before attempting to light 4 Rotate Heater Control Knob to ON position Heater burner will light and be visible through screen of heater If Main burner does not light turn off Heater Control Knob and return to Step 1 3 Pilot Light will ignite and be visible through Pilot Viewing Port flame may be difficult to see in broad daylight...

Page 12: ...ing Never use flammable or cor rosive cleaning agents For stainless steel surfaces use a stain less steel cleaner available at most retail stores While cleaning your unit be sure to keep the area around the burner pilot assembly and mantle area dry at all times If the reg ulator is exposed to water in any way do NOT try to use it It must be replaced Air flow must be unobstructed Keep controls burn...

Page 13: ...rn Cylinder valve OFF and replace cylinder Blockage in orifice Clear blockage Control knob is not in ON position Turn control knob to ON Igniter fails Use match to light pilot Obtain new igniter and replace Burner flame is low Gas pressure is low Turn Cylinder valve OFF and replace cylinder Outdoor temperature is less than 40 F Use a full cylinder and tank is less than 1 4 full Supply hose is bent...

Page 14: ...p Mantle 5040 0801 Hardware Kit Complete 13 5040 4481 Three Panels Painted Copper Vein 5040 4461 Three Panels Stainless Steel 14 5040 4781 Post Painted Copper Vein 5040 4711 Post Stainless Steel 15 5040 1751 Base Assembly with Wheels 16 5040 4881 Post Mount Painted Copper Vein 5040 4841 Post Mount Stainless Steel 17 5040 1381 Post Mount Cover Painted Copper Vein 5040 1281 Post Mount Cover Stainles...

Page 15: ...n 1 5040 1081 Table Assembly Painted Copper Vein 5040 1021 Table Assembly Stainless 2 5040 0881 Table Support Hardware Painted Copper Vein 5040 0891 Table Support Hardware Painted Silver 3 5040 0181 Clamp Painted Copper Vein 5040 0191 Clamp Painted Silver 1 2 3 ...

Page 16: ...S DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU IMPLIED WARRANTIES Any implied warranties either statutory or otherwise including implied warranties of merchantability and fitness for a particular purpose shall be limited to the duration and terms of the express warranties set forth in this limited warranty...

Reviews: