SETUP AND DRIVE OPERATION
INTRODUCTION AND GENERAL DESCRIPTION
This air-powered pump drive, when used with a MASTERFLEX
®
L/S
®
Pump Head, is
an excellent variable-flow pump for hazardous-duty applications, when properly
grounded, or when electrical power is not available.
VARIETY OF PUMP HEADS ACCEPTED
Mount up to 2 MASTERFLEX
®
L/S
®
Pump Heads and all MASTERFLEX
®
L/S
®
-
compatible Pump Heads. See individual Pump Heads for flow rates.
SETUP AND DRIVE OPERATION
1. Unpack the drive. Save packing material until proper product operation has
been verified.
2. Install pressure gauge, pressure regulator/lubricator/filter assembly (B, C) and
muffler (D). See Figures 1 and 2 for proper orientation. (All items and fittings
included.) Use thread seal for all connections to reduce the possibility of air
leakage.
3. Connect compressed air line to 1/4 NPT(F) connection on regulator (or use
adapter for 3/16 in ID hose provided).
4. Mount Pump Head and load tubing. (See Pump Head manual.)
5. Turn on compressed air line to start pumping (maximum: 150 psig [10.3 bar]
inlet).
6. Adjust flow rate with the adjustment knob on top of the regulator.
Vary flow rate from 1 to 25 psig (0.07 to 1.72 bar). (Lock flow rate by using
snap-action push-pull knob.)
CAUTION:
Ensure that pump speed does not exceed 600 rpm. Speeds
higher than 600 rpm may damage pump.
7. For continuous-duty or high-speed applications, use of the lubricator is
recommended. Adjust the lubricator with the adjustment knob on top.
For higher speeds, set lubricator to provide 1 to 3 drops per minute. Use a lower
setting for lower speeds. See MAINTENANCE for RECOMMENDED LUBRICANTS.
(Lock lubrication rate by using snap-action push-pull knob.)
Fig. 2 Top view of drive
Fig. 1 Front view of drive
A. Pump Head Mounting Holes
B. Filter/Regulator Control Knob
C. Lubricator Control Knob
D. Muffler
E. Air Motor
A
C
B
B
C
D
E
EU Declaration of Conformity
Name of Apparatus: MASTERFLEX
®
Air-Powered L/S
®
Drive with Pump Head
Model Number: 77931-10
Description of Apparatus: Peristaltic Pump Motor Drive and Pump Head. Used to
pump fluids.
Barnant Company declares that the above model is in conformity to the following
harmonized standards and directives:
Applicable Applicable
Manufacturer’s
Directive
Specifications
Report Number
89/392/EEC
EN 292-1: 1991
TR9525
91/368/EEC
EN 292-2/A1: 1995
93/44/EEC
93/68/EEC
Manufacturer:
Barnant Company Division
Cole-Parmer Instrument Company
28W092 Commercial Avenue
Barrington, IL 60010-2392
USA
Tel.: 847-381-7050
Manufacturer’s Signature:
25 August, 2000
James W. Doll
Date
Vice President, Engineering
4
5