4 \ USER OPERATION MANUAL: 

Cole-Parmer Basic Ductless Fume Hood Series

 

 

 

 

 

Warranty

 

The manufacturer agrees to correct for the original user of the product, either by repair (using new or refurbished parts), or 
at the manufacturer’s election, by replacement (with a new or refurbished product), any defects in material or workmanship 
which develop during the warranty period. The standard warranty is twelve (12) months after delivery of the product for Non-
Consumable and Electrical parts, excluding Filters and other Consumables. In the event of replacement, the replacement 
unit will be warranted for the remainder of the original warranty period or ninety (90) days, whichever is longer. For purposes 
of this limited warranty, “refurbished” means a product or part that has been returned to its original specifications. In the 
event of a defect, these are your exclusive remedies. 

 

 

If the product should require service, contact the manufacturer’s/supplier’s office for instructions. When return of the product 
is necessary, a return authorization number is assigned and the product should be shipped, transportation charges pre-paid, 
in either its original packaging or packaging affording an equal degree of protection to the indicated service center. To 
ensure 
prompt handling, the return authorization number must be placed on the outside of the package. A detailed explanation of 
the defect should be enclosed with the item. The warranty shall not apply if the defect or malfunction was caused by 
accident, neglect, unreasonable use, improper service, acts of God, modification by any party other than Cole-Parmer, or 
other causes not arising out of defects in material or workmanship.  
 
EXCLUSION OF IMPLIED WARRANTIES. THERE ARE NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, 
BUT NOT LIMITED TO, THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WHICH 
EXTEND BEYOND THE DESCRIPTION AND 

PERIOD AS STATED IN THE OPERATOR’S MANUAL INCLUDED WITH 

EACH PRODUCT. LIMITATION ON DAMAGES. 

THE MANUFACTURER’S SOLE OBLIGATION UNDER THE WARRANTY 

IS LIMITED TO THE REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT AND THE MANUFACTURER SHALL 
NOT, IN ANY EVENT, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND RESULTING 
FROM USE OR POSSESSION OF THIS PRODUCT. 
 
Some states do not allow: (A) limitations on how long an implied warranty lasts; or (B) the exclusion or limitation of 
incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you 
specific legal rights and you may have 

other rights that vary from state to state. 

 

 

 

Summary of Contents for 78900-00

Page 1: ...me Hoods USER OPERATION MANUAL l Revision No PURAIR BASIC SERIES V4 2020 pictured Model P5 XT with optional velomete Specifications are subject to change without notice or obligation 78900 00 78900 01...

Page 2: ...Importance of Performance Validation Certification 16 3 7 Disclaimer 16 IV Operating Your Cabinet 17 4 1Control System 17 4 2 CabinetOperating Procedure 18 V Monitoring 19 5 1 General 19 5 2 Manual M...

Page 3: ...hemical radiological or other non microbiological hazards are being used in the cabinet additional protective measures should be taken Additionally the operation should be monitored by a suitably trai...

Page 4: ...egree of protection to the indicated service center To ensure prompt handling the return authorization number must be placed on the outside of the package A detailed explanation of the defect should b...

Page 5: ...g further 2 1 Step By Step Procedure 1 Inspecting the Crate Pallet Boxes Upon receipt of your new cabinet inspect all cartons If there is any visible damage to the exterior please refer to Damaged Fre...

Page 6: ...against the ground will damage the pallet and possibly your new cabinet When removing cabinet from pallet or placing cabinet onto pallet use at least two people 6 Removing the Strapping Remove the str...

Page 7: ...e face velocity of the filter the potential exists for contaminated air to enter the work zone of the cabinet A minimum distance of 50 cm 20 in to the top of the ceiling is recommended for blower chan...

Page 8: ...r Cabinet 1 Please refer to Unpacking Your Cabinet page 5 2 Inspect your cabinet carefully Should you find any defect please contact customer service 3 Peel off any protective masking that was left on...

Page 9: ...3 Appropriate number of personnel are on hand two people recommended Fume Hood Assembly 1 Unpack fume hood enclosure and set on top of casework In most cases the enclosure is shipped fully assembled...

Page 10: ...es of the cutout Two tabs are bent at 90 to allow it to hinge down into the workzone Once installed lay the pre filter on top of the tray 4 Main filter now requires a painted metal hat frame to be pla...

Page 11: ...tack the second filter on top of the first with the gasket side down Make sure the corners are squared up to ensure proper installation 8 Place the white metal hat frame on top of the filter 9 Rotate...

Page 12: ...nut and set aside DO NOT DISCARD 12 Remove any tape on the airflow sensor which is used to protect the sensor wires Install the sensor by attaching to the enclosure with the screw and nut 13 If not al...

Page 13: ...f meter just below the screw b Carefully remove vane from plastic bag and cardboard envelope two vanes are enclosed one is a spare Hang the vane by the wire in the two slots provided in the vane holde...

Page 14: ...replaced with the spare vane The vaneometer is accurate to 5 of full scale from 0 100 fpm and 10 from 100 fpm to 400 fpm The permanent mounting bracket provided in the box is not used 16 Removable yel...

Page 15: ...e the blanking panel currently installed on the side of the fume hood 2 Remove the mounting screws in each corner of the blanking panel and disconnect the panel from the fume hood 3 Align the waste ch...

Page 16: ...rmance Validation Certification An airflow velocity value that falls below the value specified inside the test report will not provide adequate operator protection 3 7 Disclaimer The performance of th...

Page 17: ...tch up to turn on The green indicator lamp will illuminate to confirm the power is on The fan will start and the internal task light unit will illuminate Low Airflow Alarm The alarm status is displaye...

Page 18: ...ring the filter block may temporarily reduce the efficiency of the filter For this reason any major spillage must be cleared up immediately preferably using spillage absorption granules rather than pa...

Page 19: ...ct operating height using an anemometer such as a hot wire vane anemometer or propeller type Depending on the size of the cabinet a series of readings are to be taken at the front opening these are to...

Page 20: ...d also be noted that fume cabinets are sometimes used to contain and protect users of the cabinet from hazardous or harmful substances Before commencing this schedule it is important to ensure the cab...

Page 21: ...tial pressure switch to detect a high vacuum situation when the pre filter is blocked or blocking up The pressure switch is calibrated and tested prior to leaving our factory and under normal circumst...

Page 22: ...ialist company NOTE CONSULT YOUR SAFETY OFFICER OR INDUSTRIAL HYGIENIST BEFORE REMOVING OR DISPOSING ANY FILTERS Pre Filters The pre filter is located below the main filter Remove the perforated pre f...

Page 23: ...ly the front and top of the cabinet to remove any accumulated dust When needed use soap or other household mild detergent Quarterly 1 Replace pre filters 2 All monthly activities Annually 1 Replace al...

Page 24: ...heck Low Airflow Alarm Check airflow at aperture Check pre filter is not blocked Check fan is running Recalibrate Filter Saturated Optional Check filter condition with Gastec or Draeger test kit Check...

Page 25: ...RSONNEL WARNING Ensure main power supply has been removed prior to any work being carried out Light Units To change a light unit use the following instructions 1 Ensure the power cord has been disconn...

Page 26: ...binations to best suit your specific application HEPA filters are available for applications involving particulates and can be combined together with any of our activated carbon filters 7 1 Filter Des...

Page 27: ...27 USER OPERATION MANUAL Cole Parmer Basic Ductless Fume Hood Series VIII Product Specifications...

Page 28: ...Ductless Fume Hood Series Cole Parmer 625 East Bunker Court Vernon Hills IL 60061 1844 Ph 1 800 323 4340 Fax 1 847 247 2929 www coleparmer com info coleparmer com 78900Basic_rev_1 0 2020 Cole Parmer...