Cole Parmer 120v: 04801-20 User Manual Download Page 2

Figure 2 - Rear view

Figure 1 - Front view

HEAT

STIR

HOT

Power

on/of

f

4

3

2

1

off

5

6

7

‘Hot’ warning light

LED heat display

Stirrer 

on 

light

Temperature 

Controller 

indicator

HEAT

STIR

HOT

100

50

Power

on/of

f

h e a

t - s t

i r

US15

2

150

200

250

4

3

2

1

off

5

6

7

IEC power 

socket for 

hot condition

plug

Retort 

rod 

fitting

DIN socket

Power on/off 

switch

(not on stirrer 

only unit)

Power on green light

h e a t - s t i r

US152

HOT

1

2

3

4

5

6

7

8

9

STIR

u n d e r g r a d

off

Power
on/off

100

150

250

200

300°C

50

HEAT

Power
on/off

100

150

250

200

300°C

50

HEAT

HOT

1

2

3

4

5

6

7

8

9

STIR

o

ff

Power

on
/of
f

HEA

T

HOT

Power

on
/of
f

HEA

T

Figure 5 - Stacked on side view (as viewed from above)

Figure 3 - Front panel (analog versions)

Figure 4 - Front panel (digital versions)

‘Hot’ warning light

Stir on 

light

Stir control

Heat control

HOT

1

2

3

4

5

6

7

8

9

STIR

off

Power
on/off

HEAT

Power
on/off

HEAT

‘Hot’ warning light

Stir on 

light

Stir control

Heat control

Temperature 

Controller 

indicator

HOT

1

2

3

4

5

6

7

8

9

STIR

off

Power
on/off

100

150

200

250

350

300

450°C

50

HEAT

2

Temperature 

Controller 

indicator

Summary of Contents for 120v: 04801-20

Page 1: ...Version 1 0 HEAT STIR HOT Power on off 4 3 2 1 off 5 6 7 Range of Hotplates Stirrers User Guide...

Page 2: ...2 3 4 5 6 7 8 9 STIR off Power on off HEAT HOT Power on off HEAT Figure 5 Stacked on side view as viewed from above Figure 3 Front panel analog versions Figure 4 Front panel digital versions Hot warni...

Page 3: ...ded may be impaired Electrical Installation THIS EQUIPMENT MUST BE GROUNDED Before connection please ensure that the line supply corresponds to that shown on the rating plate located on the base of th...

Page 4: ...NOT use combustible substances near hot objects Never lift or carry the instrument until it has been switched off and allowed to cool for at least 30 minutes The hot warning light will give guidance...

Page 5: ...he control dial to the required temperature which will be shown on the LED display The temperature will increase in 5 C 41 F steps A few seconds after setting the temperature the display will revert t...

Page 6: ...roller The illuminated contact thermometer indicator LED indicates communication between the temperature controller and hotplate see Figure 3 When used in monitor mode the controller operates as a dig...

Page 7: ...nd if necessary use a mechanical overhead stirrer Do not use glass vessels with thick walls e g Pyrex Heavy Duty Ware or standard beakers and flasks having capacities of 5 liters 170 fl oz or greater...

Page 8: ...085 F or 9 9 C 14 F Er4 Hotplate Ambient Error If the temperature sensed inside the hotplate not the plate temperature is 85 C 185 F Er5 Character Error An unknown character was received from the temp...

Page 9: ...unit free of charge This warranty does NOT apply if A ceramic top has broken due to mechanical impact scratching chipping or chemical etching Any repair has been made or attempted other than by the m...

Page 10: ...z or 230V 50Hz or 230V 50Hz or 230V 50Hz or 230V 50Hz Hotplates 230v 04801 26 230v 04801 22 120v 04801 24 120v 04801 20 Plate material Coated Glass ceramic aluminum silicon Plate dimensions 150 x 150m...

Page 11: ...2 CP UNDERGRAD CERAMIC STIRRER 6x6 230V 04801 50 CP UGRAD CERAM STIRRER 6x6 120V60HZ 04801 62 CP UNDERGRAD CERAMIC HEAT STIR 6x6 230V 04801 60 CP UGRAD CERAM HEAT STIR 6x6 120V60HZ 04801 66 CP UGRAD C...

Page 12: ...For technical sales or servicing information contact Cole Parmer 625 East Bunker Court Vernon Hills IL 60061 1844 Toll Free 800 323 4340 Phone 847 549 7600 Fax 847 247 2929 www coleparmer com...

Reviews: