background image

INSTALLATION/ OPERATION

IMPORTANT!!!  PLEASE READ BEFORE INSTALLATION

1) If the unit has recently been transported please let unit stand still for a minimum of 24 hours before 
plugging it in.
2) Make sure that the unit drops down to desired temperature before loading the unit with product.
3) Make sure that there is proper ventilation around the unit in the area where it will operate.
4) Make sure all accessories are installed (i.e. shelves, shelf clips, casters) before plugging the unit in.
5) Please read through the Operation / Owners Manual in its entirety.  Lack of maintenance or misuse of 
the unit will VOID warranty.  Please fill out the registration card and send it to the factory.

CABINET LOCATION GUIDELINES

1)  Install the unit on strong and leveled surfaces

-unit may make unpleasant noises if surface is uneven
-unit may malfunction if surface is uneven

2)  Install the unit in an indoor, well-ventilated area

-unit performs more efficiently in a well-ventilated area
-for best performance, please maintain clearance of 3" on the back of the unit
-outdoor use may cause decreased efficiency and damage to the unit

3)  Avoid installation in a high humidity and/or dusty area

-humidity could cause unit to rust and decrease effeciency of the unit
-dust collected on condenser coil will cause unit to malfunction.  Clean the condenser at least 
once a month with a brush or clean cloth
-malfunction due to dirty condenser will void warranty

4)  Select a location away from heat and moisture-generating equipment

-high ambient temperatures will cause the compressor to overwork, leading to higher energy bills 
and gradual breakdown of the unit
-malfuNction due to high ambient temperature will void warranty

ELECTRICAL

Please ensure that the required voltage of the compressor is being supplied at all times.  Low or high 
voltage can detrimentally affect the refrigeration unit and thereby void its warranty.
All units should be plugged into a grounded and properly-sized electrical outlet with appropriate 
overcurrent protection.  Please refer to the electrical requirements on the unit serial tag located inside the 
unit.  Please make sure that your unit has its own dedicated outlet.  Do not use an extension cord.

-3-

BACK              

SIDE VIEW 

            FRONT

Sandwich Preps / Undercounters

3.0" 

REAR 

CLEARANCE 

REQUIRED

BACK             

SIDE VIEW 

          FRONT

NO

 

REAR 

CLEARANCE 

NECESSARY

Pizza prep units

Summary of Contents for U1BFF-06S

Page 1: ...igerators Freezers Models U1BRR 06S U1BFF 06S U2BRR 12S U2BFF 12S This manual contains important information regarding your new ColdTech unit Please read the manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maintenance guidlines outlined in this manual may void warranty MUST READ COMMERCIAL REFRIGERATOR AND FREEZER OWNER S MANUAL ...

Page 2: ... ColdTech cabinet 4 Damage to parts due to misuse abuse neglect or accidents 5 Premium labor rates due to holidays overtime travel time mileage etc not specifically authorized by Jimex Corp prior to service 6 Repairs due to modifications to the ColdTech unit or refrigeration system including remoting location of compressor s door hinge reversal etc 7 Claims for indirect or consequential damages in...

Page 3: ...sed efficiency and damage to the unit 3 Avoid installation in a high humidity and or dusty area humidity could cause unit to rust and decrease effeciency of the unit dust collected on condenser coil will cause unit to malfunction Clean the condenser at least once a month with a brush or clean cloth malfunction due to dirty condenser will void warranty 4 Select a location away from heat and moistur...

Page 4: ...own time the evaporator fan continues to circulate air through the evaporator coil This air circulation raises the coil temperature above the freezing point melting any accumulated frost Run off water is drained into the evaporator pan and evaporated Freezer coils are defrosted electrically Automatic defrost timers are built in to the refrigeration system and may not be adjusted The defrost timers...

Page 5: ...use damage to the compressor 1 To minimize shock and fire hazards please do not plug or unplug the cord with wet hands 2 During maintenance and cleaning please unplug the unit 1 To minimize shock and fire hazards make sure that the unit is properly grounded 1 Do not attempt to remove or repair any component unless instructed by factory 2 Make sure that the unit is not resting on or against the ele...

Page 6: ...o not use steel wool caustic soap abrasive cleaners or bleach that may damage the stainless steel surface Wash door gaskets on a regular basis preferably weekly Simply remove door gasket from the frame of the door soak in warm water and soap for thirty 30 minutes dry with soft cloth and replace Check door gaskets for proper seal after they are replaced Periodically remove the shelves and pilasters...

Page 7: ...ondenser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make sure thermostat is not set too cold Ensure that door gasket s are sealing properly Cabinet temperature is Thermostat set too warm Set thermostat to lower too warm temperature Blocking air flow Re arrange product to allow for proper air flow Make sure there is at least four inches of clearanc...

Page 8: ...d procedures are not followed warranty claims will be denied Notice ColdTech reserves the right to make changes in design and specifications without prior notice MODEL _______________________________ SERIAL _______________________________ PURCHASE DATE _______________________ 1575 Zephyr Ave Hayward CA 94544 800 314 4477 510 477 3400 f 510 477 3413 www coldtechUSA com ...