Logbook 

 

For your own safety and as an aid to personal responsibility, we recommend the keeping of a logbook for the 
entire period during which the fan is in service. 
All events should be recorded in the logbook. 
In case of damage and also in case of an accident, this document is the first source of information. 
For example, enter the date and your signature: 

Start and end of a work cycle 

 Special events, even if they do not concern the fan itself (e.g. power failure, alarm) 

Change of supervision staff (e.g. in case of shift operation), 

Repairs carried out and spare parts installed, 

Putting out of operation, 

Special instructions, 

etc. 

 

11 

Disposal 

 
Before disposing of plastics and other components (complete or as broken parts), please clean them as 
necessary to avoid any danger to the environment. 
Dispose of the components properly. Instruct a waste disposal company to do this or return them to us for 
disposal. 
 

12 

Troubleshooting 

 
If faults occur, we recommend you identify and clear them using the following table. 
If the fault cannot be cleared, please contact our customer service department. 
 

Fault 

Possible causes 

Remedy 

Fan not running smoothly 

Impeller imbalance 

Rebalance by specialist 
company 

Impeller caked up 

Clean carefully rebalance if 
necessary 

Material corrosion on impeller 
due to aggressive conveyed 
medium. 

Consult the manufacturer 

Impeller deformed due to high 
temperature. 

Consult the manufacturer. 
Install new impeller. 
Check bearings 

V-belt drive not correctly 
aligned. 

Adjust belt drive 

V-belt torn or damaged 

Normal wear and tear 

Replace V-belts in sets 

V-belt pretensioned too strongly 

Tension replacement belt to 
manufacturer’s specifications 

V-belts slip due to 

Incorrect pretension 

Check belt tension and retighten 
if necessary 

Foreign bodies or soiling in 
grooves or pulleys 

Clean pulleys and check belt 
profile 

Leak at shaft bushing 

Seal not suitable for application  Consult the manufacturer 

Leak on sleeves 

Sleeves defective 

Replace sleeves 

Tensioning straps not tight 
enough 

Retighten tensioning straps 

Fan output too low 

Incorrect rotation direction of 
impeller 

Change rotation direction 

Pressure losses in ducts too 
high 

Change duct arrangement 

Restrictors not or only partly 
open 

Check opening on site 

Summary of Contents for CMVeco 125

Page 1: ...Subject to alteration Copyright by COLASIT AG Spiez Page 1 OPERATION MANUAL CMVeco 125 400 Plastic industrial fan Agent Order No Fan type Year of manufacture For use in Ex zones Not for use in Ex zon...

Page 2: ...deserves your full attention please read it carefully The contents of this operating manual are subject to change without notice in order to take technical progress into account The manual contains ic...

Page 3: ...RCENCY STOP 11 6 Operation 11 6 1 Safety instructions 11 6 2 Putting out of operation 11 7 Maintenance repair cleaning 12 7 1 Preparation 12 7 2 Performance 13 8 Spare parts 14 9 Operating instruction...

Page 4: ...ator has notified us of the gas mix and the maximum operating temperature the suitability and any applicable restrictions will be confirmed in the data sheet of COLASIT AG In the absence of a written...

Page 5: ...damage nor that the fan will cause any damage 1 5 Personnel qualifications The fan may only be put into operation handled operated maintained and cleaned by trained personnel who are authorised and c...

Page 6: ...peration It may only be put into operation again when the safety devices are fully functional again Overpressure If the fan is operated in overpressure conditions with normal seals there is a danger o...

Page 7: ...ment connected to it has not been installed and checked out and until the operating manual has been read completely before commissioning We stipulate that the fan may only be put into operation when t...

Page 8: ...ding terminal of the motor and fan must be connected to a potential equalization system Motors with protection type e are standard for using in the explosion proof design of our fans The standard vers...

Page 9: ...form The signed form must be kept by the safety officer or operating company COLASIT also offers a comprehensive installation service for fans 3 Shipping unpacking inspection storage The fan is comple...

Page 10: ...ter or condensate into the fan To ensure this please use the COLASIT condensate drain nozzles Due to the possibility of noise nuisance we recommend that the fan should not be installed in the immediat...

Page 11: ...is installed To interrupt the power supply an EMERGENCY STOP switch must be provided It is advisable to mount this switch in the vicinity of the emergency exit Please request confirmation from an in...

Page 12: ...ushed with fresh air and be condensate free Fan must be at room temperature Personal protective equipment must be available and it must be worn Use of protective gloves because of sharp edges ear prot...

Page 13: ...learance between the impeller and casing minimum 1 of intake diameter maximum 20mm Measure the vibrations at bearings KA or motor DA Alarm according to ISO 14694 3 7 kW categorie BV 2 14 0 mm s r m s...

Page 14: ...ent Solvents can corrode the material These may only be used with the written consent of COLASIT To carry out cleaning work we recommend the production of a process instruction 8 Spare parts Please id...

Page 15: ...If faults occur we recommend you identify and clear them using the following table If the fault cannot be cleared please contact our customer service department Fault Possible causes Remedy Fan not r...

Page 16: ...ories If not already a part of our scope of supply these original parts are available ex stock when ordered Frequency converters Elastic sleeves Vibration dampers Condensats drains Motor cover for out...

Page 17: ...n CH 3700 Spiez Phone 41 0 33 655 61 61 Fax 41 0 33 654 81 61 TD 000 674 E Edition 4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 17 16 Dimensional drawings 16 1 Dimensions of the CMV...

Page 18: ...construction CH 3700 Spiez Phone 41 0 33 655 61 61 Fax 41 0 33 654 81 61 TD 000 674 E Edition 4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 18 16 2 Dimensions of the CMVeco 125 400...

Page 19: ...Assembly instructions 17 1 Assembly instructions CMVeco 125 400 with direct drive 1 Attach motor to the support 2 Attach casing to the support 3 Fasten impeller with the clamp adapter set on motor sh...

Page 20: ...Edition 4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 20 17 2 Assembly instructions for CMVeco 125 400 with V belt drive 1 Install flanged bearings and support plates 2 Bolt motor br...

Page 21: ...Subject to alteration Copyright by COLASIT AG Spiez Page 21 5 Fasten impeller with clamp adapter set on motor shaft Do not tight yet the clamp adapter 6 Fasten inlet section on the casing 7 Adjust im...

Page 22: ...1 0 33 654 81 61 TD 000 674 E Edition 4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 22 18 Spare parts lists 18 1 Spare parts list for CMVeco 125 400 with direct drive 1 Support 2 Cas...

Page 23: ...4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 23 18 2 Spare parts list for CMVeco 125 400 with V belt drive 1 Support 8 Feet motor 2 Casing 9 Motor plate with bracket 3 Inlet section...

Page 24: ...ction CH 3700 Spiez Phone 41 0 33 655 61 61 Fax 41 0 33 654 81 61 TD 000 674 E Edition 4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 24 Part 3 Certification 19 Certifications 19 1 EU...

Page 25: ...purpose in explosive atmospheres in compliance with Annex II of the Directive The following harmonised standards were applied EN 1127 1 Explosive atmospheres Explosion protection Part 1 2012 EN 13463...

Page 26: ...ne 1 2 an explosion proof motor with temperature class T4 must be fitted If an explosion proof motor with temperature class T3 is used temperature class T3 shall apply to the entire fan Ambient temper...

Page 27: ...2016 Subject to alteration Copyright by COLASIT AG Spiez Page 27 19 3 Further certificates This operating manual has the following certificates enclosed Datasheet of the fan ATEX Certification Inspect...

Page 28: ...are connected close to the fan With free intake blow off fans a protective grating with a mesh width of 10mm is fitted The clearance between the impeller and the casing is min 5mm and max 20mm All rot...

Reviews: