All parameters can be changed from the control panel. The “
+
” key or the “
–
” key are used to scroll through the parameter list, to
reach the parameter you want to set. Once you have selected the parameter you want, touch the
Standby
key and you will see its
current value.
To change the parameter’s value touch the
“ + ”
or
“ – ”
keys until you reach the value you want.
To confirm the value touch the
Standby
key, returning to show the parameter list, to go forward or back to a different parameter to
set it.
After setting the parameters you want, you must reach the last parameter of the “qU” list (touching the “ + ” key until
you get to it), and confirm the completed configuration by touching the Standby key from this parameter, to exit saving all
changes.
3.5.1 Parameter list
P.
Description
Range
Default value
FA
Unit regulation:
- Litres (10 L, 12 L, 15 L, 17 L)
- Gas type (G20, G31, G30, G25, G230)
1 - 15
CETI 10
CETI 12
CETI 15
CETI 17
G20 G31 G30 G25 G230 G20 G31 G30 G25 G230 G20 G31 G30 G25 G230 G20 G31 G30 G25 G230
1
2
3
4
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
PH
MAXIMUM Pressure – Entire burner
20 - F0 9d
b7 A5 b3 A8 b7 dE C1 C6 b7 9A bC A6 A9 9d A9 d3
b2 bC AC
FH
Maximum fan speed – Entire burner
20 - F0 95
A1
A2
7c
91
A4
A3
A3
A4
A3
bb
Ad
b4
A5
bb
Cd
d1
Cd Cd Cd
PL
Minimum pressure – Entire burner
20 - F0 6c
6F
6F
6c
6F
6c
6F
6F
6c
6F
71
7d
75
7B
74
71
7d
75
7B
74
FL
Minimum fan speed – Entire burner
20 - F0 4E
4d
4d
4E
4d
4E
4d
4d
4E
4d
67
64
62
67
67
67
64
62
67
67
dH
Start-up pressure
20 - F0 83
8F
8F
83
8F
83
8F
8F
83
8F
80
A0
A0
84
83
80
A0
A0
84
83
dF
Fan speed during Start-up
20 - F0 5F
4d
4d
5F
4d
5F
4d
4d
5F
4d
6A
60
75
6A
6A
6A
60
75
6A
6A
P1
Maximum pressure – Burner minimum section
20 - F0 C1 dA
dA C1 dA C1 dA
dA C1 dA
A8
F0
d6
b7
Ab
A8
F0
d6
b7
Ab
F1
Maximum fan speed – Burner minimum section
20 - F0 9b
98
98
9b
98
9b
98
98
9b
98
dA C3 C8 dA
dA
dA C3 C8 dA
dA
P2
MINIMUM Pressure – Burner minimum section 20 - F0 6d
75
71
6E 6E
6d
75
71
6E 6E 6E
83
7b
72
71
6E
83
7b
72
71
F2
Minimum fan speed – Burner minimum section
20 - F0 53
4A
4A
53
4A
53
4A
4A
53
4A
6d
77
76
6d
6d
6d
77
76
6d
6d
P3
Maximum pressure – Burner section 2
20 - F0
-
-
-
-
-
-
-
-
-
-
97
bF
b1
A0
9A
97
bF
b1
A0
9A
F3
Maximum fan speed – Burner section 2
20 - F0
bE
A3
Ad
bE
bE
bE
A3
Ad
bE
bE
P4
Minimum pressure – Burner section 2
20 - F0
66
70
6d
68
69
66
70
6d
68
69
F4
Minimum fan speed – Burner section 2
20 - F0
45
4E
4E
45
45
45
4E
4E
45
45
P5
Maximum pressure – Burner section 3
20 - F0
A5
d3
b6
b3
A8
A5
d3
b6
b3
A8
F5
Maximum fan speed – Burner section 3
20 - F0
C9 C8 C8 C9 C9 C9 C8 C8 C9 C9
P6
Minimum pressure – Burner section 3
20 - F0
71
80
77
75
74
71
80
77
75
74
F6
Minimum fan speed – Burner section 3
20 - F0
64
69
69
64
64
64
69
69
64
64
HC
Fan safety cut-off speed at Maximum Pressure
20 - 89
67 Hz
67 Hz
82 Hz
82 Hz
LC
Fan safety cut-off speed at Minimum Pressure
20 - 89
34 Hz
34 Hz
56 Hz
56 Hz
nE
Burner continuous operation timing
OFF /
20 - 60
60 min
nP
Enable or Disable Operational State memory
OFF - ON
ON
FC
Enable or Disable Solar Energy Function
OFF - ON
OFF
S1
Solar function – ON hysteresis
1 - 20
10 °C
S2
Solar function – OFF hysteresis
1 - 20
10 °C
t1
Solar function – Initial time to turn the burner on
0 - 20
10 s
nS
Maximum hot water temperature Setting
50 - 65
50 °C
nL
Caudal de agua mínimo para Inicio/Parada
-- 0: 4/3.5 L/min -- 1: 3.5/3 L/min -- 2: 3/2.5 L/min
-- 3: 2.5/2 L/min -- 4: 2/1.5 L/min
0 - 4
2
(3/2.5 L/min)
qU
EXIT and SAVE changes
-
-
Notes:
The parameters that show different values, vary the operating mode (never the range) in relation to the initial FA parameter
(water he-
ater model according to the type of Gas and Litres).
The parameters marked in gray (from P3 to F6) only appear in the real parameter
list if the FA value is between 6 and 15
(that is, for the 15 Litres and 17 Litres models)
.
71
EN