Figure 1
Coin Acceptors, Inc. 300 Hunter Avenue St. Louis, MO 63124-2013 (314) 725-0100
Coin Acceptors, Canada 237 Finchdene Square Scarborough (Toronto), Ontario M1X 1B9 (416) 297-5520
Coinco Publication No. 920859 Rev. 3 9/97 Printed in the U.S.A.
INSTALLATION INSTRUCTIONS
1. Remove the acceptor from the changer by
releasing the acceptor studs from the
changer latches and pulling the top of the
acceptor forward and away from the
changer. Unplug the ribbon cable from
the changer. Free the lower acceptor
studs from the changer housing. With the
acceptor removed, set the key holes in the
back of changer housing over the
mounting screws in the vendor. Tighten
snugly.
2. Set the desired changer options (see
Option Switch Setting section).
3. Replace the acceptor by inserting bottom
acceptor studs into changer housing
guides. Plug the acceptor ribbon cable
into the changer. Press the top of acceptor
into the changer housing until the top
acceptor studs lock into the changer's
acceptor latches.
4. Plug the changer into the vendor socket.
5. Load the coin tubes making sure all coins
lie flat.
6. Test the changer with a variety of coins to
ensure proper operation.
OPTION SWITCH SETTING
1. Unplug the coin changer.
2. Remove the acceptor.
3. Located in the upper portion of the
changer is a single switch module with
three rocker switches (see Figure 1).
When the top of the rocker switch is
pushed in, it is in the ON position. For
information regarding switch settings,
see Figure 2.
4. Replace the acceptor.
5. Plug the changer into the vendor socket.
6. Test with a variety of coins to ensure
proper operation.
SWITCH A - NOT USED
SWITCH B - LO 25¢
Controls the level of the 25¢ change tube.
ON
Quarters are directed to cash box
once change tube has approximately
18 quarters.
OFF Quarters are put into change tube
until change tube is full.
SWITCH C - $ ACPT
Controls the acceptance of the dollar coin.
ON
Dollar coin accepted.
OFF Dollar coin rejected.
Figure 2