6X-1029C
7700-2
TECHNICAL REFERENCE
Table 11. Operating Modes (continued)
ITEM
MODE
DESCRIPTION
6
PARTIAL
READOUT
(Not available in synchronous snapshot mode)
Available in the Vertical Frame.
Starting line and ending line are selectable in increments of 4
• Full Readout: Starting at line 0, ending line 1033
• Normal Readout Top: starting line 0, ending line (any increment of 4)
• Normal Readout Center: starting line (any increment of 4), ending line any
increment of 4 greater than the starting line.
• Normal Readout Bottom: starting line (any increment of 4), ending line 1033
7
RESET CONTROL
• Manual Reset: External reset button inside behind rear panel - accessible with
paper clip through hole
• Power-up Reset: Camera always powers up to its most recent operating mode
8
SERIAL CON
-
TROL
Access through camera link serial interface
• LVDS asynchronous serial communications between camera and frame
grabber
• Controls all configuration and operation functions (including factory adjustments)
• 9600 baud rate
• 1 start bit, 1 stop bit, no parity, no handshaking
• See camera protocol included in table 12 of this manual
9
OUTPUTS
Access through camera link MDR connector
• Video data: 10 bit
• Sync outputs: Horizontal (line valid) drive, vertical (frame valid) drive
• Clock output: Pixel clock (40 MHz, 25 ns)
10
CAMERA POWER
Access through power input: dedicated 3-pin connector
12 ±1.2 V dc, 500 mA, input to rear panel
11
LENS
Standard CS mount lens (or C-mount with 5 mm adapter ring)
12
DEFAULT
SETTINGS
Default settings are those in which the camera is shipped. There is also a default
mode command which when executed will set the camera mode to the default
mode listed.
• Camera defautl mode is continuous, full resolution, implicit multiple line shut
-
ter (512). Gain and offset registers set to the value of the gain and offset default
registers.
End
Summary of Contents for 7700-2 SERIES 1004 X 1004
Page 16: ...16 6X 1029C 7700 2 TECHNICAL REFERENCE Figure 11 Sensor Area Timing...
Page 17: ...17 6X 1029C 7700 2 TECHNICAL REFERENCE Table 12 Protocol...
Page 18: ...18 6X 1029C 7700 2 TECHNICAL REFERENCE Table 12 Protocol continued...
Page 19: ...19 6X 1029C 7700 2 TECHNICAL REFERENCE Table 12 Protocol continued...
Page 20: ...20 6X 1029C 7700 2 TECHNICAL REFERENCE Table 12 Protocol continued...
Page 21: ...21 6X 1029C 7700 2 TECHNICAL REFERENCE Table 12 Protocol continued...