Page 1: ...HeliosTM Products INSTALLATION MANUAL 3120HD Series Dome Positioner System July 15 2014 Technical Manual 6X 1109E www CohuHD com info CohuHD com...

Page 2: ...huHD Manufactured System Cables CA275 Series 12 3 0 Mounting Methods 13 3 1 Wall Mount CohuHD p n 7411420 001 13 3 2 Pole Mount CohuHD p n 8518 2 14 3 3 Installation Procedures 15 4 0 Quick Check 18 4...

Page 3: ...y CohuHD Costar LLC CohuHD Costar LLC has intellectual property rights to technology embodied in the product described in this manual CohuHD and Helios are trademarks of CohuHD Costar LLC FCC complian...

Page 4: ...tly display the RMA number on the outside of the shipping container s and on paperwork contained inside Give a brief description of why the equipment is being returned and list the symptoms of any pro...

Page 5: ...d to the pole For installation on a non grounded or insulated support the camera must be grounded with an adequate ground strap or wire between the camera and a nearby ground system or to a ground sys...

Page 6: ...l interfaces are via Ethernet network connection For more information on specifications and datasheets please refer to the CohuHD website 1 1 Product Description Camera Top NOTE See Section 3 3 for in...

Page 7: ...mation on each type of mount see Chapter 3 of this manual Cables CA275 Series CohuHD p n 7411275 For more information on cables see Section 2 4 of this manual PoE Injector PoE Injector CohuHD p n 7411...

Page 8: ...s Figures 1 2 and 3 show interconnection diagrams for the 3120HD series cameras Figure 1 shows a setup for the camera system using IP output and 24 Vac power Figure 2 shows a setup for the camera syst...

Page 9: ...ation The PoE injector selected for use with 3120HD must meet the following requirement Be compatible with the IEEE 802 3at standard Please refer to the following website for more in formation http en...

Page 10: ...ires insulated for 300 V minimum 18 AWG cord for power Use for distances up to 80 feet 29 m for 24 Vac cables For Alarm I O Four wires insulated for 300 V minimum 24 AWG Use for distances up to 250 fe...

Page 11: ...input and the Alarm Common MS connector pin G will generate an alarm event CAUTION Do not connect a power source to the alarm inputs Alarm Outputs Pins N and P on the MS connector connect to Alarm 1 O...

Page 12: ...th limitation is due to Ethernet signal degradation which increases with cable length The CA275A CA275C and CA275D cables are built using a single cable See cable drawings The CA275B cable Maximum cab...

Page 13: ...hased with the camera 3 1 Wall Mount CohuHD p n 7411420 001 Installation to a Wall Wall Mount Dimensions in inches mm 18 00 457 2 6 50 165 1 4 50 114 3 6 00 152 4 8 00 203 2 75 19 0 0 31 9 5 THRU 4X 7...

Page 14: ...THRU 2X 2 46 62 4 7 00 177 8 2 75 69 8 Pole Mount Adapter Dimensions in inches mm Installation to a Pole Quick Disconnect top screws directly into mount 1 5 inch NPT pipe Three stainless steel straps...

Page 15: ...mounting on A wall Use the mount as a template Mark and drill holes in the mounting surface Drill a hole for the cable if required A pole Position the pole mount adapter on the pole and secure with t...

Page 16: ...ctor Orient the dome properly and attach it to the other half of the Quick Disconnect mounted to the arm by engaging the pins and rotating approximately 1 16 inch turn CW Ensure that safety strap bolt...

Page 17: ...6X 1109E 17 Overall Dimensions in inches mm NPT National Pipe Thread 8 34 211 83 10 42 264 66 11 05 280 67 7 00 177 8 3 00 76 20 3 32 84 32 1 77 44 95 1 5 NPT...

Page 18: ...1920 x 1080 or better resolution Web Browser Microsoft Internet Explorer version 8 or 9 4 2 IP Control and Viewing of Camera Installation and testing of the camera system can be performed with the bui...

Page 19: ...ommunication tab The Communications tab is used for performing network configuration of the camera Changes to this tab can only be made by the Admin account Care must be taken when modifying parameter...

Page 20: ...Click on the Start Discovery button A list of cameras will be automatically displayed NOTE Use the MAC Address or Model Index to identify CohuHD cameras 00 09 f2 identifies cameras as CohuHD cameras...

Page 21: ...ccessing the camera using the Helios Web Interface see Operation Manual 6X 1090 If the camera system does not operate when power is applied check for Proper input voltage Proper cable connections Afte...

Page 22: ...al 6X 1090 5 1 Camera Housing Pressurization Before shipping from the factory dry packs of desiccant are secured inside the camera housing The hous ing is then sealed and purged with dry nitrogen to r...

Page 23: ...lve NOTE Preferred gas for pressurization is dry nitrogen Argon is an acceptable substitute Do not use compressed air as it may contain oil moisture or other contaminants Below are steps for rechargin...

Page 24: ...el Rev C 4 7 14 the manual is revised to add Section 2 4 Alarm Input Output Rev D 4 24 14 the manual is revised to add CA275C and CA275D cables Shipment statement Rev E 7 15 14 the manual is revised t...