Chapter 5: Programming commands
39
A776-PG00001 D 07/13
A776 (B780) Programming Guide
Set vertical line spacing
ASCII
ESC 3
n
Hexadecimal
1B 33
n
Decimal
27 51
n
Value of
n:
Receipt -
n
/406 inch
Slip -
n
/144 inch
Range of
n:
0 – 255
Default:
Receipt - 0.13 inch (3.37 mm or 7.52 lines
per inch, 3 extra dot rows)
Slip -
0.14 inch (7.20 lines per inch,
3 extra dot rows)
Sets the line spacing for the receipt and for the slip. For the receipt, the space is set to
n
/406 inches. For the slip, the line
spacing is set to
n
/144 inches. The line spacing equals the character height when n is too small.
Line spacing is set for the station or stations selected by the command 1B 63 31 n .
If the set horizontal and vertical minimum motion units command (1D 50) is used to change the horizontal and vertical
minimum motion unit, the parameters of this command (set line spacing) will be interpreted accordingly.
Related information
For more information, see the description of the set horizontal and vertical minimum motion units command
in this document.
In addition, see “Configure line spacing” (1F 03 46
n
).
Set horizontal tab positions
ASCII
ESC D [
n
]
k
NUL
Hexadecimal
1B 44 [
n
]
k
00
Decimal
27 68 [
n
]
k
0
Value of
n:
Column number for tab minus one.
(
n
is always less than or equal to the
current selected column width)
Value of
k:
0–32 (decimal)
Default:
Every 8 characters from column
1 (9, 17, 25, etc.) for normal print.
Sets up to 32 horizontal tab positions
n
columns from column one, but does not move the print position. See the
horizontal tab command (09).
The tab positions remain unchanged if the character widths are changed after the tabs are set. The command ends
with hexadecimal 00; hexadecimal 1B 44 00 clears all tabs.
Tabs assumed to be in strictly ascending order. A tab out of order terminates the command string as if it were 00, and
remaining tab values are taken as normal data.
Formulas
Set the tab positions in ascending order and put Hex 00 at the end.
Hex 1B 44 00 (number of tabs not specified) clears all tab positions.
Exceptions
The tabs cannot be set higher than the column width of the current pitch.
Summary of Contents for A776 ColorPOS
Page 12: ...Contents x A776 B780 Programming Guide A776 PG00001 D 07 13...
Page 14: ...Chapter 1 About this Guide 2 A776 B780 Programming Guide A776 PG00001 D 07 13...
Page 172: ...Code page 1255 Hebrew...
Page 173: ...Code page KZ_1048 Kazakh Code Page KZ_1048 Kazakh...
Page 174: ...Appendix C Electronic Journal 162 A776 B780 Programming Guide A776 PG00001 D 07 13...
Page 179: ......
Page 180: ...A776 PG00001 Rev D 07 2013...