General-Purpose Outputs
The I/O module extends the capabilities of the vision system by providing eight independent, general-purpose outputs
(OUT 0 - OUT 7) that can be used to trigger remote events. General-purpose outputs are optically isolated and are
typically connected (directly or indirectly) to a load (such as a relay, indicator light or motor). Refer to
for common wiring configurations.
CAUTION
:
All general-purpose outputs share a common connection (OUT COMMON). Therefore, all output
devices must be the same; either current sinking or current sourcing. Mixing outputs with sinking and sourcing
could damage the I/O module or your devices.
Specification
Description
Voltage
30VDC maximum (24VDC nominal)
Current
100mA (max), auto-reset fuse protection
Delay
Module 150µs (maximum delay due to the I/O module)
Total
2ms (time between an input state change and completion of transmission to the supported In-Sight
vision system)
29
Specifications