RS-232 Receive and Transmit
The vision system can be connected to an RS-232 interface, which is non-isolated. When enabled, the RS-232
RECEIVE signal replaces IN 1, and the RS-232 TRANSMIT signal replaces HSOUT 1.
Specification
Description
Resistance
>10 kOhms
Baud rates
4800, 9600, 19200, 38400, 57600 and 115200.
Data Bits
7, 8
Stop Bits
1, 2
Parity
None, even and odd.
Handshaking
Software: Xon/Xoff.
Hardware: None.
1
RS-232 Connector Configuration
The Breakout cable can be used to connect to an RS-232 connector. For more information, refer to the
Tip
: If the serial signal output is not detected, make sure the 24V COMMON line is connected between the RS-232
device and the vision system.
1
If hardware handshaking is required, an I/O module must be used.
29
Specifications