High-Speed Outputs
In-Sight 5000 series vision systems feature two built-in, high-speed outputs. Both of the high-speed outputs are NPN
(current sinking) lines. The external load should be connected between the output and the positive supply voltage
(28VDC or less). The outputs pull down to 0.1VDC or less when ON (1.25VDC or less for In-Sight 5604 only), which
causes current to flow through the load. When the outputs are OFF, no current flows through the load.
Table 3-7: High-Speed Output Specifications
Specification
Description
Voltage
28VDC maximum through external load.
Current
All In-Sight 5000 series
(except In-Sight 5600 series)
200mA maximum sink current.
OFF state leakage current 200µA maximum.
External load resistance 140 Ohms to 10 kOhms.
Each line rated at a maximum 200mA, protected against over-
current, short circuit and transients from switching inductive loads.
High current inductive loads require external protection diode.
In-Sight 5600 series
100mA maximum sink current.
OFF state leakage current 200µA maximum.
External load resistance 280 Ohms to 10 kOhms.
Each line rated at a maximum 100mA, protected against over-
current, short circuit and transients from switching inductive loads.
High current inductive loads require external protection diode.
Delay
12
±5µs (maximum due to opto-isolators turning ON).
High-Speed Output - NPN Configuration
The Breakout cable can be used to connect to an NPN-compatible PLC input. Connect HS OUT 0 or HS OUT 1 directly to
the PLC input. When enabled, the output pulls down the PLC input to 0VDC. For more information, refer to
.
Figure 3-3: High-Speed Output - NPN Configuration
1
Delay when opto-isolators turn OFF depends on the load to which the output is connected. With a 240 Ohm load, the maximum delay will be
±5µs.
2
If HS OUT 1 is configured as a Strobe output type within In-Sight Explorer, the maximum strobe latency is ±5µs. For more information, refer to
the
In-Sight
®
Explorer Help
file.
Specifications
19
Summary of Contents for In-Sight 5000 Series
Page 1: ...In Sight 5000 Series Vision System InstallationManual...
Page 2: ......
Page 4: ...ii...
Page 8: ...vi...
Page 10: ...viii...
Page 12: ...x...
Page 20: ...8...
Page 41: ...Figure 3 11 5600 and 5603 Vision System Dimensions Without Lens Cover Specifications 29...
Page 43: ...Figure 3 13 5604 and 5605 Vision System Dimensions Without Lens Cover Specifications 31...
Page 44: ...32...
Page 46: ...34...
Page 47: ......
Page 48: ...P N INS 597 0027 07 Rev B...