Installation
This section describes the connection of the vision system to its standard and optional components. For a complete list of
options and accessories, contact your Cognex sales representative.
Note
:
l
Cables are sold separately.
l
If any of the standard components appear to be missing or damaged, immediately contact your Cognex
Authorized Service Provider (ASP) or Cognex Technical Support.
CAUTION
:
All cable connectors are “keyed” to fit the connectors on the vision system; do not force the connections
or damage may occur.
Connectors and Indicators
Table 2-1: Vision System Connectors and Indicators
Connector/Indicator
Function
24VDC Connector
Connects the Breakout cable, which provides connections to an external power
supply, the acquisition trigger input, high-speed outputs and RS-232 serial
communications. For more information, refer to
. Alternately, this connector is used to attach the I/O Module cable to an
optional In-Sight I/O module, which adds general-purpose discrete I/O and light
control functionality. For more information, refer to the
User 1 LED
Green when active. User configurable using Discrete Output Line 4 (Line 10 for all
I/O modules, except the CIO-1400, which uses Line 9).
User 0 LED
Red when active. User configurable using Discrete Output Line 5 (Line 11 for all
I/O modules, except the CIO-1400, which uses Line 10).
Power LED
Green when power is applied.
Network Traffic LED
Flashes green while transmitting and receiving data.
Network Status LED
Green when a network connection is detected.
ENET Connector
Connects the vision system to a network. The ENET connector provides the
Ethernet connection to external network devices. For more information, refer to the
Note
:
l
For the In-Sight 5100 and 5400 series, when the vision system is powered up, User 0 LED and User 1 LED
both momentarily turn on. Then, User 0 LED turns off and User 1 LED stays on. Next, User 0 LED turns on
and User 1 LED turns off. Finally, both LEDs momentarily turn on and then turn off.
l
For the In-Sight 5600 series, when the vision system is powered up, User 0 LED and User 1 LED both
momentarily turn on. Then, User 1 LED turns off and User 0 LED stays on. Next, User 1 LED turns on and
User 0 LED turns off. Finally, both LEDs momentarily turn on and then turn off.
5
Summary of Contents for In-Sight 5000 Series
Page 1: ...In Sight 5000 Series Vision System InstallationManual...
Page 2: ......
Page 4: ...ii...
Page 8: ...vi...
Page 10: ...viii...
Page 12: ...x...
Page 20: ...8...
Page 41: ...Figure 3 11 5600 and 5603 Vision System Dimensions Without Lens Cover Specifications 29...
Page 43: ...Figure 3 13 5604 and 5605 Vision System Dimensions Without Lens Cover Specifications 31...
Page 44: ...32...
Page 46: ...34...
Page 47: ......
Page 48: ...P N INS 597 0027 07 Rev B...