I/O Module Cable Specifications
The I/O Module cable is used with the CIO-1400 I/O expansion module. The I/O Module cable connects the vision sensor
directly to the I/O module via the DB15 connector. When the I/O module is used, all power and communication lines used
by the vision sensor are connected using the I/O Module cable.
P1 Pin#
Signal Name
Wire Color
Signal Name
P2 Pin#
1
HS OUT 2
Yellow
Not Used
Not Used
2
RS-232 Tx
White/Yellow
RS-232 Rx
7
3
RS-232 Rx
Brown
RS-232 Tx
6
4
HS OUT 3
White/Brown
Not Used
Not Used
5
IN 0
Violet
Not Used
Not Used
6
INPUT COMMON
White/Violet
TRIGGER-
3
7
+24VDC
1
Red
+24VDC
1
8
GND
1
Black
-24VDC
8
9
OUTPUT COMMON
Green
-24VDC
8
10
TRIGGER
Orange
2
11
HS OUT 0
Blue
HS OUT 0
4
12
HS OUT 1
Grey
HS OUT 1
5
Note
:
l
Cables are sold separately.
l
The CIO-1400 I/O expansion module supports In-Sight 2000 series vision sensors with firmware version
5.3.0 and higher.
1
Not applicable to PoE models.
52