In-Sight® 1400 I/O Expansion Module Installation and Reference Manual
31
5.
Open the drop-down list to the left of the OK button and select CIO - 1400. The
Discrete Output dialog will automatically reconfigure to correspond to the 1400 I/O
Expansion Module, as shown in
Figure B-4: Discrete Output Dialog, Expansion module Configuration
6.
Configure the discrete output line settings - Line Name, Type and Details (see
Appendix A) and click OK to save the new settings to the sensor’s memory. See
Appendix A for a basic overview of the Discrete I/O Settings. The
In-Sight
®
Explorer
Help
file contains a more detailed explanation of these settings.
7.
Select OK to save the new settings to the sensor's memory.
Notes:
• The sensor can also be configured to recognize the 1400 I/O Expansion Module by
selecting Discrete Input Settings from the Sensor menu and following steps
.
• When a .JOB file containing a WriteDiscrete function is loaded on an In-Sight sensor
to which the I/O Expansion Module has just been added, the Start Bit and Number of
Bits parameters in WriteDiscrete must be changed to reflect the new configuration of
the I/O lines.