16  Deluxe I/O Box Quick Reference Guide

Deluxe I/O Box Quick Reference Guide   17

Weight

3.43 kg

Operating 

Temperature

0ºC — 45ºC (32ºF — 113ºF)

Storage Temperature

-10ºC — 60ºC (-14ºF — 140ºF)

Maximum Humidity

95% (non-condensing)

Environmental 

Protection 

IP54

Vibration

Up to 20G

Power Supply

110V to 240V AC

Input Voltage

24 DC (+/- 10%); 150 W

Operating current 

at 24V

6A

Specifications 

i

NOTE: For product support, contact http://support.cognex.com

CAUTION: IP protection is ensured only when all connectors are attached 

to cables or shielded by a sealing cap. 

Warnings and Notices

TO FOLLOW THESE INSTRUCTIONS MAY CAUSE SERIOUS INJURY

•  CAUTION - Use of controls or adjustments or performance of procedures other 

than those specified herein may result in hazardous radiation exposure.  

•  Do not attempt to service or repair this product -- return it to Cognex for 

service.  

•  Do not permit anyone other than Cognex Corporation to service, repair, or 

adjust this product. 

•  Do not attempt to open or modify this device except as described in this 

document.

•  Do not operate this device if it is damaged or if the covers or seals are missing 

or damaged. 

 FAILURE 

Summary of Contents for Deluxe I/O Box

Page 1: ...COGNEX Deluxe I O Box Quick Reference Guide...

Page 2: ...ng Started About the Deluxe I O Box Cables Page 4 1 Connecting a Camera Page 10 3 Connecting Cameras Trigger Wiring 1 4 Compliance Information Warnings and Notices Specifications Warnings and Notices...

Page 3: ...ring and power point to support up to four camera units and allows these the possiblity to easily connect to their industrial environment The Deluxe I O Box supports the following units DataMan 300 Da...

Page 4: ...Master Deluxe I O Box Layout Cable Glands to Wire Peripherals Mounting Points Input Terminals Output Terminals Illumination Power Outputs Power Indicator Extension module slot for future release SD ca...

Page 5: ...cable glands 26 mm Mounting Instructions Always use a flat and solid surface and use all four mounting holes for maximum safety Observe safety regulations when mounting the unit Make sure the cable gl...

Page 6: ...y connect a camera to the Deluxe I O Box 3 If you are using trigger wiring unscrew the cable gland cover pluck out the plastic cover and thread in the trigger wire Then screw the cover tightly and use...

Page 7: ...Connect your camera s using the CKR 200 CBL EXT extension cable Optionally the DM300 family readers can be connected via Ethernet while the DM503 can also be connected via Ethernet and RS 232 connecto...

Page 8: ...to a reader You can power up the reader using the M12 connector and you can use trigger wiring to have the reader start reading at a specified trigger The image below presents an example of trigger w...

Page 9: ...d only when all connectors are attached to cables or shielded by a sealing cap Warnings and Notices TO FOLLOW THESE INSTRUCTIONS MAY CAUSE SERIOUS INJURY CAUTION Use of controls or adjustments or perf...

Page 10: ...tion is to operate them according to the agency guidelines that follow Please read these guidelines carefully before using your device European Compliance The CE mark on the product indicates that the...

Page 11: ...he written permission of Cognex Corporation The hardware and portions of the software described in this document may be covered by one or more of the U S patents listed on the Cognex web site http www...

Reviews: