![Cognex DataMan 8600 Series Reference Manual Download Page 14](http://html1.mh-extra.com/html/cognex/dataman-8600-series/dataman-8600-series_reference-manual_2634713014.webp)
3. Connect the DataMan 8600 to your PC.
4. Launch the DataMan Setup Tool and click
Refresh
. The reader or the base station appears under
COM ports
or
Network devices
.
5.
Select a
COM port
or a
Network device
and click
Connect
.
DataMan 8600 Specifications
Weight
303 g (without slide-in),
345 g (with tethered slide-in)
Operating Temperature
0ºC — 45ºC (32ºF — 113ºF)
Storage Temperature
DataMan 8600 wireless: -10ºC — 45ºC (14ºF — 113ºF),
DataMan 8600 tethered: -40ºC — 60ºC (-40ºF — 140ºF)
Maximum Humidity
< 95% (non-condensing)
Environemntal
IP65
Codes
1-D barcodes
: Codabar, Code 39, Code 128, and Code 93, Interleaved 2 of 5,
Pharma, GS1 DataBar, Postal, UPC/EAN/JAN, DataBar
2-D barcodes
: Data Matrix
TM
; QR Code and microQR Code, RSS/CS, PDF 417,
MicroPDF 417
Power Supply Requirements
USB: external 5.0 W maximum LPS or NEC class 2 power supply: +5V - +6V DC
RS232 external 5.0W max LPS or NEC class 2 power supply
+6.0V 1A DC (5.0m RS-232 cable)
+6.0V 1A DC (2.5m RS-232 cable)
ETH: Class 2 PoE supply IEEE 802.3af (connect only to PoE networks without routing
to the outside plant)
Inrush current peak
5A maximum
Duration: approx. 30μs
Electrical charge: 60μAs at 6V
Battery life for wireless reader
(typical use case)
ca. 2900 triggers can be operated within a 10 hour working shift
Ethernet
10/100 Base-T FULL/HALF DUPLEX, IEEE 802.3
Bluetooth
Bluetooth™ 2.1, 2.4 GHz
WiFi
802.11 b/g, 2.4 GHz, User Selectable channels 1-11
14