DataMan 470 Specifications
Specification
DataMan 470
Weight
373 g with S-mount adapter, without rubber front cover
Power
Consumption
l
24 VDC ±10%, 1.5 A maximum (HPIL* and HPIT**)
l
24 VDC , 250 mA maximum (non-HPIL)*
l
24 VDC, 1000 mA (HPIA)***
Supplied by LPS or NEC class 2 only.
*HPIL denotes one of the DM360-HPIL-xxx-xx or DMLT-HPIL-xxx-xx accessories.
**HPIT denotes one of the DMLT-HPIT-xxx-xx accessories.
***HPIA denotes one of the DM30X-HPIA3-xxx-xx accessories.
Light
Connector
Output Voltage
20 V – 26.4 V
Voltage may drop below nominal input
voltage depending cable length.
Max avg Current
1 A
Peak Operating Current
1.5 A up to 100 µs, avg to not exceed 1 A
Max Inrush Current
5 A not exceeding 0.4 As
Case
Temperature
1
0°C – 57°C (32°F – 134.6°F)
Operating
Temperature
2
0 °C – 40°C (32 °F – 104°F)
Storage
Temperature
-20°C – 80°C (-4°F – 176°F)
Humidity
< 95% non-condensing
Environmental IP67 with cables and appropriate lens cover attached.
1
Additional cooling measures may be required to keep the case temperature from exceeding 50°C. Examples of
such measures include: extra heat sinking and/or air movement.
2
In situations where the operating temperature exceeds 40 °C, an external heat sink is required.
30
Summary of Contents for DataMan 470 Series
Page 1: ...DataMan 470 Series Quick Reference Guide 2021November25 Revision 6 1 11 1...
Page 17: ...DataMan 470 Series with High power Illumination Accessory HPIA 17...
Page 18: ...DataMan 470 Series with High Power Integrated Torch HPIT 18...
Page 19: ...DataMan 470 Series with High Power Integrated Torch HPIT and Passive Diffuser 19...
Page 33: ......
Page 38: ......
Page 40: ......