background image

DataMan

®

360 Series

Quick Reference Guide

2020 October 05
Revision: 6.2.1.1

Summary of Contents for DataMan 360 Series

Page 1: ...DataMan 360 Series Quick Reference Guide 2020October05 Revision 6 2 1 1...

Page 2: ...Cognex Corporation to service repair or adjust this product l Do not attempt to open or modify this device except as described in this document l Do not direct or reflect laser light toward people or...

Page 3: ...llumination mounting point 4 Mounting holes M3 x 5 mm 5 Indicator light ring 6 Trigger button 7 Power 8 Train status 9 Read no read indicator 10 Network 11 Error 12 Peak meter 13 Tuning button 14 Ethe...

Page 4: ...M12 lens with locking DM300 LENS 10 DM300 LENS 10 IR Liquid lens module and pre focused 10 3 mm or 10 3 mm IR M12 lens with wrench DM300 LENS 10LL DM300 LENS 10LL IR 19 mm liquid lens module DM300 LE...

Page 5: ...35 mm F8 fixed aperture lens LEC CFF35 F8 35 mm F11 fixed aperture lens LEC CFF35 F11 35 mm F16 fixed aperture lens LEC CFF35 F16 40 mm F11 fixed aperture lens LEC CFF40 F11 40 mm F16 fixed aperture l...

Page 6: ...ion RiskGroup Exempt acc IEC 62471 DM300 CLCOV WHI Diffuse lens cover with red LED illumination with blue LED illumination with IR LED illumination Polarizer lens cover with red LED illumination RiskG...

Page 7: ...RiskGroup Green LED AimerExempt acc IEC 62471 DM360 HPIL WHI Red LED high powered integrated light 24 mm lens RiskGroup Red LED Exempt acc IEC 62471 DMLT HPIL RE Polarized red LED high powered integra...

Page 8: ...HPIA Red narrow DM30X HPIA3 625 HPIA Red wide DM30X HPIA3 625 W HPIA Red narrow with polarizer DM30X HPIA3 625P HPIA Red wide with polarizer DM30X HPIA3 625P W HPIA White narrow DM30X HPIA3 WHI HPIA W...

Page 9: ...ble M12 12 straight xx specifies length 5m 10m 15m angled xx specifies length 5m 10m 15m CCB PWRIO xx CCB PWRIO xxR Connection cable RS 232 CCB M12xDB9Y 05 Power cable for multiple bar lights use in c...

Page 10: ...U UK or JP DMA CCM 4X xx or DMA CCM 1 xx External light mounting brackets xx specifies light type may get used in combination with DM100 PIVOTM 00 or DM500 BRKT 000 if pivoting is required DM300 ELMB...

Page 11: ...Dimensions A S Mount M12 Lens version B C Mount Lens version 11...

Page 12: ...ading Distances Note Due to tolerances ranges can vary by 5 from unit to unit 10 3 mm lens green 16 mm lens red 25 mm lens blue inner DM360 inner DM360 inner DM360 outer DM362 DM363 outer DM362 DM363...

Page 13: ...code 16 mm lens Distances in mm 1D min code 16 mm lens DM360 DM362 59 72 2 MIL 60 125 2 MIL 55 207 4 MIL 55 270 4 MIL 49 295 8 MIL 56 400 6 MIL DM363 35 190 5 MIL 45 400 7 MIL 30 420 10 MIL 45 495 13...

Page 14: ...stances in mm 1D min code 19 mm lens DM360 inner brown DM362 outer black 61 97 2 MIL 59 173 2 MIL 58 167 4 MIL 56 322 4 MIL 58 310 8 MIL 56 471 6 MIL DM363 outer black 61 109 2 MIL 29 199 2 MIL 58 192...

Page 15: ...ed Device Distances in mm 2D min code 24 mm lens Distances in mm 1D min code 24 mm lens DM360 DM362 80 120 2 MIL 80 230 2 MIL 80 230 4 MIL 80 460 4 MIL 80 460 8 MIL 80 690 6 MIL DM363 80 150 2 MIL 80...

Page 16: ...is not grounded a ground wire should be added in compliance with local electrical codes CAUTION To reduce emissions connect the far end of the Breakout cable shield to frame ground Perform the followi...

Page 17: ...elect the following to access the manual All Programs Cognex DataMan Software vx x x Documentation Note l Cables are sold separately l If a standard component is missing or damaged immediately contact...

Page 18: ...a ground wire is used it should be attached to one of the four mounting points on the back plate of the reader not to the mounting points on the front of the reader Mounting the DataMan reader at a sl...

Page 19: ...connector 2 Connect the Ethernet cable s RJ 45 connector to a switch router or PC as applicable Connect the Breakout Cable CAUTION To reduce emissions connect the far end of the Breakout cable shield...

Page 20: ...ages other than 24 VDC Always observe the polarity shown 3 Attach the Breakout cable s M12 connector to the DataMan 360 series reader s 24 VDC connector 4 Restore power to the 24 VDC power supply and...

Page 21: ...k 3 Connect the cable to a 24V power supply To configure a DataMan 360 series reader the DataMan Setup Tool software must be installed on a networked PC The DataMan Setup Tool is available from the Da...

Page 22: ...Group blue and white illuminations Risk Group 1 Low Risk No further labeling is required RS 232 RxD TxD according to TIA EIA 232 F Codes 1 D barcodes Codabar Code 39 Code 128 and Code 93 Interleaved 2...

Page 23: ...W l External illumination up to 1 2 A average 45 W peak current according to illumination these values depend on the illumination and its configuration Supplied by LPS or NEC class 2 only HPIL denote...

Page 24: ...tion at Full Resolution l DataMan 360 and 362 up to 60 fps l DataMan 363 up to 40 fps Lens Type l S Mount 10 3 mm F 5 with optional liquid lens with IR blocking filter l S Mount 16 mm F 9 no IR blocki...

Page 25: ...at 35 C 95 F 4 duty cycle for example 750 s exposure and 18493 s interval l at 45 C 113 F 2 duty cycle for example 350 s exposure and 18093 s interval or 1000 s exposure and 50000 s interval LED Wave...

Page 26: ...al equipment the best way to ensure safe operation is to operate them according to the agency guidelines that follow Please read these guidelines carefully before using your device Regulator Specifica...

Page 27: ...rence when the equipment is operated in commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions ma...

Page 28: ...ex complies with Directive 2012 19 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment WEEE This product has required the extraction and use of...

Page 29: ...vites you to use the appropriate separate take back systems for product disposal If you need more information on the collection reuse and recycling systems please contact your local or regional waste...

Page 30: ...ls PBB Polybrominated diphenyl ethers PBDE Regulatory Model 1AA4 Reguatory Model 1ABG X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 SJ T 11364 O Indicates that sai...

Page 31: ...Copyright 2020 Cognex Corporation All Rights Reserved...

Reviews: