Installing a Liquid Lens
Perform the following steps to install a liquid lens on your DataMan 260 reader.
Note
: Disconnect the DataMan 260 reader from power before installing the liquid lens.
1. Remove the front cover: unscrew the four M2x12mm Phillips Pan screws and take off the LED cover.
2. Remove the illumination module.
3. Turn the lens cap to the 105 mm position.
4. Remove the lens cap from the imager lens by pulling it.
Note
: Do not rotate the imager lens while the lens cap is removed. Otherwise, focus calibration will be lost.
27
Setting Up Your DataMan 260
Summary of Contents for DataMan 260
Page 1: ...DataMan 260 Reference Manual 08 24 2016 Version 5 6 3...
Page 19: ...19 Getting Started...
Page 32: ...DM262 6 2 mm Lens 32 Setting Up Your DataMan 260...
Page 46: ...Signal PoE Ethernet Model 46 Connections Optics and Lighting...
Page 49: ...49 Connections Optics and Lighting...