5. Attach the liquid lens accessory by aligning the 2x2 connectors of the liquid lens with the 2x2 sockets on the
optics mount.
6. Press the liquid lens onto the imager lens until you reach the stop.
7. Reattach the illumination.
8. Attach the front cover. Observing the tightening sequence below, tighten all four M2x12mm Phillips Pan screws to
9 Ncm using a torque wrench.
Note
: The rib in the front cover must be oriented to the top side.
Note
: The DataMan 150 liquid lens must be calibrated after field exchange. This can be done under
Focus
Settings
in the DataMan Setup Tool. For more information, see the
DataMan Questions and Answers
document.
A reboot is required for the lens to operate with the new settings.
25
Setting Up Your DataMan 150