Installing the MVS-8100D
Cognex MVS-8100D and CDC Cameras Hardware Manual
21
Figure 7 shows the connections to the external I/O module when used with the
MVS-8100D2 and MVS-8100D3.
Figure 7.
External I/O module connections with MVS-8100D2 and D3
4.
Attach the external I/O module to a convenient surface. It is configured for a
standard #3 DIN rail mounting.
5.
Connect a ground wire from the external I/O module’s screw terminal labeled
“Ground” to a ground point.
Caution
The external I/O module must have the same ground potential as the
chassis of the PC containing the MVS-8100D. Any difference in
potential can damage the equipment. If you connect a ground wire
to the I/O module ground screw, then that ground must have the
same potential as the MVS-8100D host’s ground.
TTL_BI_1 to IN 0
TTL_BI_3 to OUT 0
TTL_BI_4 to OUT 1
TTL_BI_5 to OUT 2
TTL_BI_6 to OUT 3
TTL_BI_7 to OUT 4
TTL_BI_8 to OUT 5
TTL_BI_2 to IN 1
TTL_BI_11 to IN 2
TTL_BI_12 to IN 3
TTL_BI_9 to OUT 6
TTL_BI_10 to OUT 7