Details Dialog Controls
1.
Pulse: When this checkbox is enabled, the output will be pulsed. Disable this checkbox for a
steady-state output. The output must be pulsed when the Acquisition Delay is greater than 0.
2.
Pulse Length (ms): Specifies the duration of an output pulse (10 to 1000 ms).
3.
Acquisition Delay (N): Specifies the number of acquisition or tracking pulses (0 to 1000) to
delay the output after a signal pulse is received by an output Line. If Acquisition Delay = 0,
then the In-Sight device updates the output line immediately on evaluating the WriteDiscrete
function. If Acquisition Delay > 0, then the output Line is always pulsed.
4.
Strobe Trigger: Rising Edge will trigger a strobe on the rising edge of the signal; Falling Edge
will trigger a strobe on the falling edge of the signal.
A.2
Configuring the Discrete Input
The Discrete Input Settings dialog (Figure A-2) configures the parallel input lines on the
active In-Sight sensor. Discrete input signals are read into the In-Sight spreadsheet using
the ReadDiscrete function. The number of accessible inputs varies per In-Sight model as
shown in Table A-4.
Strobed
Light Control
High
Low
System Busy
Online/Offline
I/O Module
Standby
No Output details are configurable for these Line Types.
Table A-4: In-Sight Discrete Input Capability by Mode
MODEL
INTEGRATED (BUILT-IN)
INPUTS
OPTIONAL INPUTS
In-Sight 3400
In-Sight 5000 Series
None
(8) additional inputs using the 1460 I/O Expansion.
Table A-3: Line Details Dialog (Continued)
LINE TYPE(S)
SAMPLE OUTPUT DETAILS DIALOG
Summary of Contents for 800-5815-1
Page 1: ......
Page 2: ......
Page 6: ...iv ...
Page 10: ...List of Figures viii ...
Page 12: ...List of Tables x ...
Page 16: ...Introduction 4 ...
Page 48: ...36 ...
Page 50: ...38 C 1 1 1460 I O Expansion Module Output to PLC Input ...
Page 52: ...40 C 1 3 1460 I O Expansion Module Output to Pilot Light Input ...
Page 54: ...42 C 1 5 1460 I O Expansion Module Input to PLC Output ...
Page 56: ......
Page 57: ... Q 6LJKW 0RGHO 2 SDQVLRQ 0RGXOH QVWDOODWLRQ DQG 5HIHUHQFH www cognex com 597 0029 02 ...