4. TECHNICAL INFORMATION
Voltage: 3V (2*1.5V AA battery)
Operation current: <6uA (standby), <75mA (alarm mode)
Alarm volume: ≥ 85 dB at a distance of 3 meters
Smoke sensitivity: 0.115-0.168dB/m
Heat sensitivity: 54-70
º
C
Guarantee: 2 years
Conform to the standard: EN14604
5. GUARANTEE
Cofem grants a 2 years guarantee, starting from the purchase date of the
product. If the smoke alarm becomes defective during the guarantee period,
the smoke alarm will be replaced with a new one if the defective one is sent
to Cofem. The guarantee covers manufacturing or material defects in the
product, if the smoke alarm has been used according to the user instructions
and the guarantee period neither has nor expired. The guarantee period for a
smoke alarm that has been replaced with a new one is the same as that of the
original smoke alarm. The guarantee is not valid if 1) the product is used,
maintained, or tested contrary to the user instructions, 2) the defect has been
caused by a negligent act by other than Cofem, or 3) if the product has been
modified or treated with force, or if it the guarantee receipt is missing. The
guarantee does not cover costs due to installation or battery replacement.
Cofem responsibility does not in any case exceed the price of a new smoke
alarm. Cofem is not responsible for any damage or loss that has been caused
by a non-working smoke alarm. This guarantee does not affect rights enacted
by law.
6. PRODUCT COMPONENTS DRAWING
7. INSTALLATION
A smoke alarm can be installed in two different ways:
(1) Quick installation with 3M double- sided tape or (2) by installing the
smoke alarm with screws.
Note: Installation with 3M two - sided tape is not approved according to
Great Britain's LPCB standard.
(1) QUICK INSTALLATION WITH 3M DOUBLE-SIDE TAPE
Make sure that the installation surface is even and cleaned thoroughly. If the
ceiling is uneven surface or rough in texture, install the smoke alarm with the
screws supplied.
Make sure that the smoke alarm is activated by pressing the test button for 1
seconds. When the smoke alarm gives an alarm sound, the testing has been
performed successfully and your smoke alarm is ready for use. The
installation is now complete.
Recommendation
: Test your smoke alarm weekly!
(2) INSTALLATION WITH SCREWS
1) Remove the mounting plate of the smoke alarm by turning it
counterclockwise and lifting it away.
2) To achieve the correct smoke alarm positioning, then mark drill holes for
the screw anchors. Install the mounting plate of the smoke alarm tightly to
the ceiling with the screws.
3) Press the smoke alarm against the mounting plate and turn it clockwise
until you feel clicks.
4) Make sure that the smoke alarm is activated by pressing the test button for
1 second. When the smoke alarm gives an alarm sound, the testing has been
performed successfully and your smoke alarm is ready for use.
5) The installation is now complete.
Recommendation
: Test your smoke alarm weekly!