CoeLux
®
45 HC
User's manual
Edition E1
Page 11 of 13
4.2.3
REPLACEMENT PROCEDURE OF SILICA GEL
Open the door [41] that enable the access to exhausted silica gel. Open the package containing
18 new silica gel bags and put them into the compartment in place of the exhausted ones. Than
close the compartment using the door [41].
Fig. 3
Replacement of silica gel
4.3
EXTRAORDINARY MAINTENANCE
WARNING:
Warranty is null and void in case of extraordinary maintenance performed without authorization
of CoeLux S.r.l. or authorised technician.
In the event of product contamination:
-
cut off device power;
-
be careful that wires and electrical parts do not come into contact with water or detergent;
-
follow the initial cleaning instructions.
If necessary:
•
Clean fans.
•
Clean the CoeLux® panel.
•
Clean mirrors.
•
Check hanging system.
•
Remove internal dirt.
•
Realign mirrors.
•
Realign the structure.
•
Repaint internal parts.
•
Replace the LED projector.
•
Replace the CoeLux® panel.
Restart the product proceeding as with initial assembly.