User Code Commands 

A) PRIVATE USE: Changing the USER CODE

#User Code 

 New User Code 

 New User Code 

••

 

Example: #0099 

 6688 

 6688 

••

 

Result: User Code now 6688. 

  

B) PUBLIC USE: Set the USER CODE

Enter personal four-digit code to lock 

 Re-enter same code to open 

••

1. When the lock is opened the User Code will be erased and ready for the next new user to enter

their code. 

2. When locked in B) Public Use Function the 

 LED will flash every two seconds indicating

locked status. 

3. Keypad in this function is only active when lever is in closed position. 

  

Special Master Code Commands 

Changing from PRIVATE USE to PUBLIC USE with TECHNICIAN CODE enabled

#Master Code 

 50 

 Technician Code  

 Technician Code  

••

 

Example: #55443322 

 50 

 555555 

 555555 

••

 

Result: The lock is automatically set into function Public Use AND allows the
programmed Technician Code to open the lock WITHOUT the entered User Code being erased. 
Note: If lock is opened with a Master Code the User Code will be erased. 

  

Changing from PRIVATE USE to PUBLIC USE without a TECHNICIAN CODE

#Master Code 

 61 

••

 

Example: #55443322 

 61 

••

 

Result: The lock will now work in Public Use
Note
:

1. The locking pin is now programmed to be withdrawn when using the above code string and is

waiting and ready to accept a User Code. Please note that the keypad is now inactive when the
lever is in the open position 

2. Only the Master Code and Sub-Master Code will be retained from Private Use Function 

  

Changing from  PUBLIC USE to PRIVATE USE

#Master Code 

 55 

••

 

Example: #55443322 

 55 

••

 

Summary of Contents for KL1200

Page 1: ...1 Master Code 55 44 33 22 2 User Code 00 99 When fitted immediately change the Master Code and User Code All Master Codes and Sub Master Codes are 8 digits long All User Codes are 4 digits long All Te...

Page 2: ...only used for programming functions when lock is in Private Use Function Master Code Open the lock Change the Master Code Set Change Delete the Sub Master and User Code Select between Private and Publ...

Page 3: ...e LED will flash twice and the lock will have reverted to the factory master code 55 44 33 22 and all other stored settings will be erased Penalty time Entering three incorrect codes will cause the lo...

Page 4: ...ds Change the MASTER CODE Master Code 65 New Master Code New Master Code Example 55443322 65 12345678 12345678 Result Master Code has been changed to 12345678 Note prefix not required when in B Public...

Page 5: ...Delete SUB MASTER CODE Master Code 63 63 Example 55443322 63 63 Result Sub Master Code deleted Note prefix not required when in B Public Use Sub Master Code Commands Change the SUB MASTER CODE Sub Ma...

Page 6: ...PUBLIC USE with TECHNICIAN CODE enabled Master Code 50 Technician Code Technician Code Example 55443322 50 555555 555555 Result The lock is automatically set into function Public Use AND allows the p...

Page 7: ...d it will once again relock for 4 hours If the lock is opened during the 4 hours period then the lock remains open until a new User Code is entered as normal Note This program will only work when the...

Page 8: ...https codelocks zohodesk eu portal en kb articles kl1200 right hand programming operating instructions POI_KL1200RH v1_0318_OL 2019 Codelocks Ltd All rights reserved...

Reviews: