background image

CODE Flame 384 User’s Manual 

http://www.codelight.com 

6

 1  ~  16  Chase number keys 

Cooperating with Chase section key, 16 Chase keys can operate A01-A16, B01-B16, C01-C16, 48 

Chases. Using    SINGLE 

 

key, single Chase or multi Chases can be operated. 

 

Edit 

 

SAVE TO SCENE

   

Scene save key

 

Save the current channel values of the scanners to a scene with some 

number. 

Set the channel values of various scanners with manual operation, or add 

some scenes, then press the key first, and press scene section key and scene 

number key. The current channel values of the scanners are saved to the number of that section. 

 

  EDIT CHASE    Chase edit key 

Press the key, the indicating light blink. It is in the Chase edit state. 

Press the key again, the indicating light is off. The edit result is saved and the edit state is quitted. 

 

SET X/Y    X/Y set key 

Write the X/Y control channel number of various scanners to the console, then use modulation wheels to 

control the position of the various scanners. 

 

  LOAD FILE / DELETE    Import Files / Delete key 

Press the key and hold 2 seconds, to import files from USB Drive or when the Chase is edited, press the 

key to delete the current Chase step. 

 

  SAVE FILE / ADD    Backup files / Add key 

Press the key and hold 2 seconds, to backup files to USB Drive or when the Chase is edited, press the 

key to add a new Chase step after the current one. 

If the current Chase step is the last one of the Chase, the parameters of the current Chase step are 

copied automatically to the new added Chase step. 

 

  ENTER / SWITCH    Enter/Switch key 

In scene edit and environment edit, it is ENTER key. 

In Chase edit, it is SWITCH key. 

  

WX

ST

 MODULATION WHEELS 

In edit Chase, 

WX

 is used to change edit item, 

ST

 is used to set the value of 

the item. 

In manual operation mode, 

WX

 is used to set the X position of a scanner, 

ST

 

is used to set the Y position. 

 

 

 

 

 

Summary of Contents for Flame 384

Page 1: ...User s Manual Ver 1 04 CODE ELECTRONIC CO LTD...

Page 2: ......

Page 3: ...the time of the program step can be changed from 0 03s to 180s 48 scanner scenes can be used directly 8 Chases 48 scenes operated at the same time At most 16 scanners can be selected simultaneously T...

Page 4: ...inside components of the console and make functions failure Scanner console is precision electric equipment Please pay attention to moistureproof protection and dustproof protection And please clean t...

Page 5: ...032 064 128 256 8 169 1 2 3 4 5 6 7 8 9 ON DIP 001 002 004 008 016 032 064 128 256 9 193 1 2 3 4 5 6 7 8 9 ON DIP 001 002 004 008 016 032 064 128 256 10 217 1 2 3 4 5 6 7 8 9 ON DIP 001 002 004 008 0...

Page 6: ...1 16 scanner can be chosen from number keyboard HOLD Scanner hold key When the indicating light is on it is a scanner hold state Multi scanner can be manual operated 1 16 Scanner number keys Press the...

Page 7: ...SINGLE light is off the current section can run multi scenes at the same time 1 16 Scene number key Cooperating with scene section key 16 scene keys can operate A01 A16 B01 B16 C01 C16 48 scenes Using...

Page 8: ...Y set key Write the X Y control channel number of various scanners to the console then use modulation wheels to control the position of the various scanners LOAD FILE DELETE Import Files Delete key Pr...

Page 9: ...h the slider to FAST Chase runs faster Push the slider to SLOW Chase runs slower Chase step Time x SPEED percentage the actual running time of the current Chase step The changeable range is 300 30 Whe...

Page 10: ...tten to the console one by one X axis of 16Bit resolution scanner is controlled by two data channels Y axis is controlled by two data channels too So X Y is controlled by 4 data channels X axis coarse...

Page 11: ...entation and the smoothness of the moving trace Auto correction to the wrong setting X L no Y L no must be set at the same time That just one is no is a mistake Flame 384 checks and corrects X L Y L t...

Page 12: ...modulation wheel ST The set range of a slider is 0 255 Whether 8bit or 16Bit X Y scanner the set range of a modulation wheel is 0 999 It represents the moving range of X axis or Y axis For 16Bit scan...

Page 13: ...hannel can be chosen at the same time 3 Use CHANNELS sliders to set the channel values Use modulation wheel WX and ST to adjust X Y position 4 Press the corresponding number key of the chosen scanner...

Page 14: ...key press C key in SCENE then press 10 key and ENTER SWITCH key Chase Edit Flame 384 console can save 48 Chases A Chase is a buildup of some Chase steps The concept of Chase step is very similar to t...

Page 15: ...ansferring from last step to next step Total time for processing is 10s 70 7s 5 Set the channel values of various scanners in the current step manually Use ENTER SWITCH key to change the setting state...

Page 16: ...NTER SWICTH key to validate Running Running scene Example 1 Single running scene A01 1 Close running scene B and C one by one 2 Press A key to choose A as the current district 3 Press SINGLE key to ma...

Page 17: ...w the above 4 Chases are running simultaneously Tips If the chosen Chase is empty without Chase step the screen will display Check the various operating parameters of multi Chases running simultaneous...

Page 18: ...fine channel low 8Bit channel Y H Y axis coarse channel high 8Bit channel Y L Y axis fine channel low 8Bit channel No For 8Bit scanner only X Y coarse channel can be used So the X Y fine channel must...

Page 19: ...er Strobe 5 PAN SGM GALILEO 6 TILT 1 PAN 2 TILT 3 Color 4 Gobo 5 Shutter 6 Dimmer Trackspot Bond scanner 7 Motor Speed 1 Strobe Fan Speed Lamp on off Reset Fixture 2 Intensity 3 Color 4 Gobo 1 Fixed G...

Page 20: ...steps in a Chase 100 Chase step time 0 1s 60s Chase gradual change ratio Cross 0 100 Total capability of Chase steps 1600 Chase amount of simultaneous running scanners 8 Music in phase Chase 10 0dB au...

Page 21: ...CODE Flame 384 User s Manual http www codelight com 19 M E M O CODE Electronic Co Ltd...

Reviews: