7
D041878
CR5200
User Manual
5
.0
- Using a
CR5200
in Presentation Mode
6.
0
- Using a
CR5200
in Handheld Mode
JNR
M
NR
PM
QR
-15°
0°
15°
30°
45°
7
.0
-
Typical Reading Ranges
Note: All samples were high quality codes and were read along a physical center line at a 10° angle. Default automatic gain control settings
were used with regular office lighting. Accuracy= +/- 10%. Testing conditions may affect working ranges. Measured from the front of the
device in metric units then converted to Imperial units.
CR5200
Performance
Test Barcode
Min Inches (mm)
Max Inches (mm)
7.5 mil Code 39
0.4
” (
1
0 mm)
5
.
9
” (
150
mm)
10.5 Mil GS1 DataBar
0
.4
” (
1
0 mm)
6.7
” (
170
mm)
13 mil UPC
0.4” (10 mm)
8
.0
” (
203
mm)
5.8 mil PDF417
0.
8
” (
20
mm)
4.0
” (
103
mm)
6.7 mil PDF 417
0.4” (10 mm)
4.
8
” (
122
mm)
5 mil Data Matrix
1
.2
” (
31
mm)
2.
3
” (
59
mm)
6.3 mil Data Matrix
0.9
” (
23
mm)
3.
5
” (
89
mm)
4 cm
10 mil Data Matrix
0.
4
” (
10
mm)
5
.
7
” (
146
mm)
20.8 mil Data Matrix
0.4” (10 mm)
8.
9
” (
225
mm)
Min Inches (mm)
Max Inches (mm)
0.4
” (
1
0 mm)
5
.
1
” (
131
mm)
0
.4
” (
1
0 mm)
5
.4” (
138
mm)
0.4” (10 mm)
6
.8
” (
175
mm)
0.
6
” (1
6
mm)
3.
2
” (
82
mm)
0.4” (10 mm)
4.
5
” (1
14
mm)
1
.0
” (
25
mm)
2.2
” (
5
5 mm)
1.1
” (
27
mm)
3.0
” (
78
mm)
0.
6
” (1
4
mm)
5
.0
” (1
26
mm)
0.4” (10 mm)
8.4
” (
213
mm)
Handheld Mode
Presentation Mode