15
2009 Audiovox Electronics Corporation. All rights reserved.
Feature Bank 3 - Output Control
1 - Extended Lock Pulse: Controls the timing of the BLUE and GREEN lock
output wires.
1 Second - Single 1 second unlock pulse.
3.5 Seconds - Single 3.5 second unlock pulse.
Double Pulse Unlock - Double 1second unlock pulse.
Feature Bank 4 - Remote Start Control
2 - Run Time: Controls the time in minutes that the vehicle will stay running
under control of the remote start until the system times out. The system may also
be shut down at any time by use of the transmitter or system shutdowns.
3 - Running Lights: Controls the WHITE parking light output wire during remote
start.
Steady - Parking lights constant during the remote start cycle.
Flashing - Parking lights flash at a slow pace during the remote start cycle.
4 - Tach Mode: Determines how the system monitors the engine running during
remote start.
Tach - Hard wired directly to the tach wire of the vehicle to monitor AC
voltage.
Tachless (Crank Average/Voltage) - Determines crank time by averaging the
last 8 times the vehicle was started with the key and then monitors the
change in voltage after remote start.
Hybrid (Crank Average / No Voltage) - Determines crank time by averaging
the last 8 times the vehicle was started with the key.
DBI Port - Monitors the vehicle’s tach rate through an interface module
connected to the DBI port.