background image

6

2009 Audiovox Electronics Corporation. All rights reserved.

8 Pin  Input Harness

3 Pin  Lock Output Harness

Summary of Contents for CA 6150

Page 1: ...1 2009 Audiovox Electronics Corporation All rights reserved PROFESSIONAL SERIES Security and Remote Start Installation Guide for models CA 6150 CA 6550...

Page 2: ...Harness 11 2 Pin Door Lock Output Harness 14 Additional Ports 18 Antenna LED Programming Port 18 DBI Port 18 Set Up Programming 19 Transmitter Programming 19 Manual Feature Programming 19 Programming...

Page 3: ...3 2009 Audiovox Electronics Corporation All rights reserved Feature Descriptions 23 Transmitter Button Functions 27 Security Trigger Zones 28 Remote Start Shutdown Diagnostics 28 System Layout 29...

Page 4: ...r hot surfaces Avoid mounting components or routing wires near moving parts Tape or loom wires under hood for protection and appearance Technical Support 800 421 3209 or go to http techservices codesy...

Page 5: ...5 2009 Audiovox Electronics Corporation All rights reserved 6 Pin Start Harness 5 Pin Main Harness 6 Pin Output Harness...

Page 6: ...6 2009 Audiovox Electronics Corporation All rights reserved 8 Pin Input Harness 3 Pin Lock Output Harness...

Page 7: ...ive switching Parking Lights Connect the WHITE RED wire to a 15 Amp max fused battery source Connect the WHITE wire to the parking light output wire Negative switching Parking Lights Connect the WHITE...

Page 8: ...he START position Cut the vehicle s starter wire in half when installing the starter kill relay Verification after starter wire is cut KEY SIDE of starter wire registers voltage when the key is turned...

Page 9: ...ge does not drop out when the key is turned to the START or CRANK position Connect the PINK WHITE wire to the vehicle s ignition 2 wire Programmable output IGN ACC Start 4 PINK IGNITION 1 Locate the v...

Page 10: ...n 3 output wire provides a ground output when the remote start function is activated and remains until 4 seconds after the remote start is shutdown The Ignition 3 output wire can be used for several f...

Page 11: ...relays For Control of optional accessories i e Power Window Sunroof etc To activate refer to the transmitter button configuration chart Please refer to the selectable options for timing 4 RED WHITE TR...

Page 12: ...fication This wire will register ground NEG when the door is opened and the interior light is on This wire will register positive voltage when the door is closed and the interior light is off Connect...

Page 13: ...fety wire of the vehicle or an optional toggle switch The remote start feature will not operate unless this input is supplied with a ground source 8 PURPLE WHITE TACHINPUT Locate the vehicle s ignitio...

Page 14: ...to see which type of door lock system is in your vehicle The most common types are shown in the following diagrams Negative Switching Locks All Door Lock and Unlock Locate the lock unlock wire at the...

Page 15: ...ed 12 Volt Battery Souce GREEN Lock Output BLUE Unlock Output Positive Locks Reverse Polarity Locks 5 Wire Door locks All Door Lock and Unlock Locate the lock unlock wire at the vehicle s lock unlock...

Page 16: ...REEN Lock Output BLUE Unlock Output Multiplex Locks 87 87a 86 30 87 87a 86 30 85 85 Fused 12 Volt Battery Source Ground Resistor Positive Multiplexed Locks All Door Lock and Unlock Locate the lock unl...

Page 17: ...aftermarket actuators not supplied Connect the GREEN and BLUE wires shown in the diagram below using 2 SPDT relays not supplied 30 87 87a 86 85 Fused 12 Volt Battery Source Door Lock Actuator 30 87 8...

Page 18: ...Door Trigger Trunk Hatch Open Door Lock Control Passlock Passkey Interface GM Only Dome Light Supervision Transponder Interface Activation Factory Alarm Arm Disarm Diesel Glow Plug Input Manual Arm D...

Page 19: ...Press and hold the valet override button 3 Within 10 seconds the system will chirp 3 three times 4 Press 1 button of each transmitter you wish to program 5 The system will respond with 1 chirp for ea...

Page 20: ...mitter programming Defaulting All Features Pressing the button anytime while in any of the feature banks will default all features and return you to feature bank 2 4 chirps NOTE The system will remain...

Page 21: ...and reengage the starter motor The Remote Start unit will learn the tach rate of most vehicle s single coil multiple coil packs or single injector To learn tach 1 Turn the ignition key to the ON posi...

Page 22: ...learning mode 4 The LED will begin to flash indicating the system has exited the learning mode and is now armed Chirp Delete User Accessible System ARM DISARM chirps can be toggled ON or OFF without...

Page 23: ...ecurity system and during a triggered cycle both the siren and horn outputs will activate respectively 5 Security Controls security functionality ON OFF ON Full security functionality OFF The security...

Page 24: ...tory Disarm Single 1 second pulse with unlock and remote start activation 2nd Unlock Single 1 second pulse with 2nd press of unlock only Start Status Continuous output during the remote start cycle 3...

Page 25: ...remote start Tach Hard wired directly to the tach wire of the vehicle to monitor AC voltage Tachless Crank Average Voltage Determines crank time by averaging the last 8 times the vehicle was started w...

Page 26: ...pe and delay time for the starter output wire during remote start activation Gas Gasoline engine no delay for the starter output wire 10 Second Delay Diesel engine delays the starter output wire for 1...

Page 27: ...Functions 11 2 or 3 Hour Start When activated the remote start will activate and run for the programmed time and shut down every 2 or 3 hours 12 Turbo Timer When activated the vehicle will run for the...

Page 28: ...shes Shock Sensor 5 Flashes Ignition Input Remote Start Shutdown Diagnostics If the remote start shuts down or fails to start the parking lights will flash one of the patterns below indicating the shu...

Page 29: ...SIREN OUTPUT RED BATTERY 12V BROWN BLACK HORN OUTPUT BLUE BLACK IGNITION 3 ACTIVE OUTPUT VIOLET BLACK AUX 1 RED WHITE TRUNK RELEASE OUTPUT LT GREEN BLACK FACTORY DISARM PULSE BEFORE START ORANGE GROU...

Page 30: ...and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received inclu...

Reviews: