Feature Bank 2 - Security

1 - Silent Choice: Controls the normal arm/disarm chirps of the security system.

ON - Silent arming/disarming upon first press of lock/unlock, pressing lock/
unlock a second time will activate the arm/disarm chirps respectively. The
system will only sound the arm/disarm chirps upon a second press of the
lock/unlock buttons.

OFF - normal arm/disarm chirps upon the first press of lock/unlock.

Feature Descriptions

Feature Bank 3 - Output Control

1 - Extended Lock Pulse: Controls the timing of the BLUE and GREEN lock output
wires.

1 Second - Single 1 second lock pulse, single 1 second unlock pulse.

3.5 Seconds - Single 3.5 second lock pulse, single 3.5 second unlock pulse.

1 Second Lock, Double Pulse Unlock - Single 1 second lock pulse, double 1
second unlock pulse.

30 Second Lock, Double Pulse Unlock - Single 30 second lock pulse, double
1 second unlock pulse.

Double Pulse Lock, 1 Second Unlock - Double 1 second lock pulse, single 1
second unlock pulse.

2 - Factory Disarm: Controls the timing of the LT. GREEN/BLACK factory disarm
output.

Factory Disarm - Single 1 second pulse with unlock and remote start
activation.

2nd Unlock - Same output as unlock with 2nd press of unlock.

Start Status - Continuous ( - ) output during the remote start cycle.

Summary of Contents for CA 5051

Page 1: ...1 2010 Audiovox Electronics Corporation All rights reserved PROFESSIONAL SERIES Remote Start with Keyless Entry Installation Guide CA 5051...

Page 2: ...rnate Harness 9 2 Pin Door Lock Harness 10 Additional Ports 14 Antenna LED Programming Port 14 DBI Port 14 Set Up Programming 15 Transmitter Programming 15 Manual Feature Programming 15 Programming Fe...

Page 3: ...r hot surfaces Avoid mounting components or routing wires near moving parts Tape or loom wires under hood for protection and appearance Technical Support 800 421 3209 or go to http techservices codesy...

Page 4: ...ing Light Harness 1 PURPLE STARTER OUTPUT MOTOR SIDE 2 RED BATTERY 12V 3 ORANGE ACCESSORY 1 4 PINK WHITE IGNITION 2 5 RED WHITE BATTERY 12V 6 PINK IGNITION 1 6 PIN START 1 LT GREEN BLACK FACTORY DISAR...

Page 5: ...icle s trunk release wire at the trunk release switch Verification This wire will register either positive voltage or ground when the trunk release is activated This is a low current output 500mA 4 BL...

Page 6: ...ill increase as the engine s RPM increases Connect the PURPLE WHITE wire to the negative side of the vehicle ignition coil or fuel injector Fused 12 Volt Battery Source 30 87 87a 86 85 BLUE BLACK Acti...

Page 7: ...a NOTE Do not ground the BLACK wire with any other vehicle components 3 Pin Parking Light Harness 7 BROWN RED BRAKE INPUT Locate the vehicle s brake light wire at the brake pedal mounted switch Verifi...

Page 8: ...Volt battery wire NOTE Remove all fuses until all connections are made 3 ORANGE ACCESSORY 1 Locate the vehicle s accessory wire at the ignition switch Verification This wire registers voltage when th...

Page 9: ...wire to the constant 12 Volt battery wire NOTE Remove all fuses until all connections are made 4 Pin Alternate Harness 1 LT GREEN BLACK FACTORY DISARM PULSE BEFORE START This wire will supply a 200mA...

Page 10: ...er Output Wire From The C ontrol Module 2 Pin Door Lock Harness 1 BLUE UNLOCK 2 GREEN LOCK The door lock unlock outputs are designed to control several different types of systems which may require add...

Page 11: ...icle Door Lock Control Relays GREEN Lock Output BLUE Unlock Output Negative Locks Positive Switching Locks All Door Lock and Unlock Locate the lock unlock wire at the vehicle s lock unlock switch Veri...

Page 12: ...12 Volt Battery Souce GREEN Lock Output BLUE Unlock Output Reverse Polarity Locks X Cut X Cut To Door Lock Motor To Door Lock Motor Negative Multiplexed Locks All Door Lock and Unlock Locate the lock...

Page 13: ...REEN wires shown in the diagram below using 2 SPDT relays not supplied Lock Unlock Vehicle Door Lock Control Relays GREEN Lock Output BLUE Unlock Output Multiplex Locks 87 87a 86 30 87 87a 86 30 85 85...

Page 14: ...ut Down Trunk Hatch Open Diesel Glow Plug Input Door Lock Control Passlock Passkey Interface GM Only Dome Light Supervision Transponder Interface Activation Factory Alarm Arm Disarm Manual Arm Disarm...

Page 15: ...stem will remain in feature programming mode as long as the ignition is on there is no time limit To exit programming turn the IGNITION OFF Set Up Programming Transmitter Programming Feature Bank 1 1...

Page 16: ...16 2010 Audiovox Electronics Corporation All rights reserved Feature Bank 1 3 Chirps Transmitter Programming Refer to transmitter programming...

Page 17: ...e unit senses the tach signal the parking lights will begin to flash 6 Allow the vehicle to settle to a normal idle speed 7 Release the valet program push button switch The parking lights will turn on...

Page 18: ...trols the timing of the BLUE and GREEN lock output wires 1 Second Single 1 second lock pulse single 1 second unlock pulse 3 5 Seconds Single 3 5 second lock pulse single 3 5 second unlock pulse 1 Seco...

Page 19: ...0mS 40mS 50mS 5 Real Panic Controls the panic out when triggered from the transmitter ON Randomized horn honks when panic is triggered OFF Standard pattern horn honks when panic is triggered Feature B...

Page 20: ...fter the engine is running may be less than 0 5 volts 6 Crank Time Preset output times for the PURPLE starter wire 1 Second 0 8 Seconds 1 5 Seconds 2 Seconds 4 Seconds 7 Crank Average Crank Time The l...

Page 21: ...te start will activate and run for the programmed time and shut down every 2 or 3 hours Transmitter Button Functions 1 Way Transmitter Lock Unlock Car Find Panic Start Operation Method Lock X Press an...

Page 22: ...the parking lights will flash one of the patterns below indicating the shutdown input To manually enter diagnostics and view the last shutdown turn the ignition ON and press and release the button LE...

Page 23: ...UNLOCK PURPLE STARTER OUTPUT MOTOR SIDE RED BATTERY 12V ORANGE ACCESSORY 1 PINK WHITE IGNITION 2 RED WHITE BATTERY 12V PINK IGNITION 1 BLACK GROUND WHITE RED PARKING LIGHT INPUT WHITE PARKING LIGHT OU...

Page 24: ...and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received inclu...

Reviews: