background image

T07890 Rev. A

Page 3 of 6

This product contains high intensity LED devices.  To prevent eye damage, DO NOT stare 

into light beam at close range.

Operation (cont.)

Flash Patterns:

The CL199 Series LED Beacon is programmed with 30 different flash patterns.  Refer the section below for instructions on how 

to set the flash pattern.

Synchronous Flash Patterns

 

FP 1:   Single Alert 75 PHASE 1 (Sim) 

FP 12:   Single Flash 150 PHASE 2 (Sim) 

 

FP 2:   Single Alert 75 PHASE 2 (Sim) 

FP 13:   Single Flash 75 PHASE 1 (Sim) 

 

 

 

FP 3:   Quad Flash 75 PHASE 1 (Sim) 

FP 14:   Single Flash 75 PHASE 2 (Sim) 

 

 

 

FP 4:   Quad Flash 75 PHASE 2 (Sim) 

FP 15:   Single Alert 75 (Alt)  

 

 

 

FP 5:   Double Flash 150 PHASE 1 (Sim) 

FP 16:   Quad Flash 75 (Alt)  

 

 

 

FP 6:   Double Flash 150 PHASE 2 (Sim) 

FP 17:   Double Flash 150 (Alt) 

 

 

 

 

FP 7:   Double Flash 75 PHASE 1 (Sim) 

FP 18:   Double Flash 75 (Alt) 

 

 

 

 

FP 8:   Double Flash 75 PHASE 2 (Sim) 

FP 19:   Single Flash 375 (Alt) 

 

 

 

 

FP 9:   Single Flash 375 PHASE 1 (Sim) 

FP 20:   Single Flash 150 (Alt) 

 

 

 

 

FP 10:   Single Flash 375 PHASE 2 (Sim) 

FP 21:   Single Flash 75 (Alt) 

 

 

FP 11:   Single Flash 150 PHASE 1 (Sim) 

Non-Synchronous Flash Patterns

 

 

 

 

FP 22:   Active Flash (Sim)   

FP 27:   Rotator 75 

 

 

 

 

 

 

FP 23:   Modular Flash (Sim) 

FP 28:   Rotator 125 

 

 

 

FP 24:   Modular Active (Alt)  

FP 29:   Rotator 250 

 

 

 

FP 25:   Modular Active (Sim) 

FP 30:   AUTORUN 

 

 

 

 

FP 26:   Rotator 50

(Sim) -Front and Rear LEDs fire simultaneously, (Alt) - Front and Rear LEDs alternate 

Synchronization (Permanent Mount Only):

To sync two beacons, configure both beacons to display the same Phase 1 pattern. With the power off, connect the YELLOW 

wires from each beacon together. When the beacons are activated, their patterns will be synchronized. 

To configure the two lightheads to alternate their patterns, advance the pattern of either beacon to the Phase 2 mode of the 

current pattern. 

Do not SYNC more than 8 beacons!

Setting the Flash Pattern:

 

Magnetic Base Version:

 

Depress the rocker switch on the lighter plug:

   

- Less than 1 second for the 

NEXT

 pattern

   

- 1 to 3 seconds for the 

PREVIOUS

 pattern

   

- 3 to 5 seconds for the 

DEFAULT

 pattern

   

- Greater than 5 seconds to 

TURN OFF

 the beacon

 

Permanent Mount Version:

 

Connect blue wire to black wire (chassis ground):

   

- Less than 1 second for the 

NEXT

 pattern

   

- 1 to 3 seconds for the 

PREVIOUS

 pattern

   

- 3 to 5 seconds for the 

DEFAULT

 pattern

   

- Greater than 5 seconds to 

TURN OFF

 the beacon

WARNING!

Reviews: