Coda LINUS5-C User Manual Download Page 21

21

3.3.2 Inrush current limitation 

The LINUS5-C has a special processor dedicated to limit the mains inrush current. This limiter will take action anytime:
- when connecting the amplifier to the mains through the mains cable,
- when switching the amplifier on through an external mains breaker, 
- the mains voltage was lost for at least 4 half-cycles or more (e.g. a short voltage drop).
This limiter will confine the mains current to a value smaller than 20 A rms*. 
*Maximum rms value of inrush current over one half-cycle of the mains voltage according to IEC/EN 55032:2016-02 
(Electromagnetic compatibility of multimedia equipment - Emission requirements: German version EN 55032:2012/
AC:2013).  

NOTE: Even under normal conditions the mains current can reach levels up to 32 A/64 A (230 V/115 V) and even higher for 
very short periods of time. This could cause lamps to flicker if connected to the same mains as the am plifier. The impedance 
of the AC circuit should be less than 0.157 Ω to avoid flicker according to EN 61000-3-11 “Electromagnetic compatibility- 
Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in the public low-voltage supply systems 
- Equipment with rated current ≤  75 A and subject to conditional connection” (IEC 77A/929/CDV:2016). If in any doubt, 
consult your local power provider. Never attempt to measure this impedance level with your Ωmeter. This may damage 
your meter and expose you to the risk of electric shock.

3.3.3 Mains power consumption and current draw 

Due to the huge outout power of LINUS5-C the mains current draw can get very high when demanding large output 
powers. Please refer to follow ing table for an overview of mains currents and power consumption under different 
operating conditions.

Mains current draw and power consumption @ 230 V, 50 Hz 
Measured with pink noise with crest factor of 12 dB to represent typical music signal. 
For 115 V mains operation, the current values can be multiplied by 2. 
Please note that the values given here are typical values only, measured on a standard 230 V/50 Hz outlet. The actual mains 
current draw can vary depending on the music signal and the mains characteristics (especially the mains impedance) of 
any specific installation.

Operating condition

Mains current (4 Ω)

Power consumption (4 Ω)

Output power

Amplifier standby 

(power off)

0.12 A

27 W

0 W

Idle (amplifier power on) 

0.51 A

115 W

0 W

75 W per channel / 1/8th

2.2 A

495 W

300 W

150 W per channel/ 1/4

3.8 A

851 W

600 W

200 W per channel / 1/3rd

5.0 A

1100 W

800 W

LINUS5-C  

3. INSTALLATION

Summary of Contents for LINUS5-C

Page 1: ...FOR USE FOR MODELS CODA AUDIO LINUS5 C The leading version of this brochure is the English one which shall prevail to the exclusion of the national translation on hand USER MANUAL v2 0 Copyright 2010...

Page 2: ...Telephone 49 0 511 866 55 888 Fax 49 0 511 866 55 887 Internet www codaaudio com Email contact codaaudio com Subject to change Please visit our website www codaaudio com for the latest version of thi...

Page 3: ...emote control inputs Ethernet 23 3 6 Power outputs 23 4 OPERATION 24 4 1 Screen user interface 24 4 2 Power amp protection 28 4 3 Mains protection 28 4 4 Mains overvoltage detection 28 4 5 Fans 28 4 6...

Page 4: ...esent on the metal casing and surrounding conductors The main power switch on the front panel is a soft switch Ensure that the mains power can be isolated from the amplifier at any time 6 Power cord p...

Page 5: ...xhibits a distinct change from its normal function or performance in case the amplifier has been used in a dusty environment for quite a period of time 14 Servicing All service and repair work must be...

Page 6: ...URE THE EXCLAMATION MARK IS INTENDED TO ALERT THE USER TO IMPORTANT INSTRUCTIONS ALSO FOR MAINTENANCE IN THE LITERATURE ACCOMPANYING THE AMPLIFIER CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN THE AMPLIF...

Page 7: ...industrial IEC EN 55103 2 2010 Immunity for all environments E1 residential to ES industrial The operating conditions and application environments presupposed in the information for use user manual ar...

Page 8: ...pr sentes sur le chassis m tallique L interrupteur lectrique tant un mod le soft assurez vous de la bonne isolation de l amplificateur par rapport l alimentation lectrique 6 Protection du cordon d ali...

Page 9: ...mode d emploi l amplificateur a t utilis dans un environnement poussi reux pendant un temps prolong 14 Entretien Toute op ration de maintenance ou r paration doit tre effectu e par un revendeur distr...

Page 10: ...CLAMATION SERT GALEMENT A AVERTIR L UTILISATEUR D INSTRUCTIONS IMPORTANTES POUR L ENTRETIEN CONTENUES DANS LA DOCUMENTATION DE L AMPLIFICATEUR ATTENTION RISQUE DE CHOC LECTRIQUE NE PAS OUVRIR L AMPLIF...

Page 11: ...munit pour tous les environnements E1 r sidentiel a E5 industriel Les conditions d utilisation ainsi que les environnements d exploitation d crits dans le mode d emploi sont respecter scrupuleusement...

Page 12: ...einem dedizierten Erdungsleiter angeschlossen werden Bei dem Verst rker handelt es sich um ein Ger t der Ger teklasse 1 welches zu jeder Zeit geerdet sein muss Fehlende Erdung kann unerwartete und hoh...

Page 13: ...h ttet Fremdk rper sind in den Verst rker gelangt der Verst rker war Regen oder Feuchtigkeit ausgesetzt der Verst rker wurde mechanisch besch digt das Netzkabel der Netzstecker sind besch digt der Ver...

Page 14: ...ER AUF WICHTIGE BEDIENUNGS UND WARTUNGSANLEITUNGEN IN DER DEM VERST RKER BEIGEF GTEN LITERATUR AUFMERKSAM MACHEN VORSICHT NICHT FFNEN STROMSCHLAGGEFAHR DER VERST RKER DARF NUR IN H HE BIS 2000 M EINGE...

Page 15: ...2 2010 St rfestigkeit f r alle Umgebungen E1 Wohngebiete bis ES gewerblich Die in den Benutzerinformationen angegebenen Betriebsbedingungen sind entsprechend einzuhalten Svetlomir Aleksandrov EU Konf...

Page 16: ...e driver and cabinet components Further benefits to this approach include substantial reductions in cost and quicker times to market for new products We have a wide product range offering high quality...

Page 17: ...PECIFICATION The LINUS5 C power amplifier is fitted with a fixed voltage power supply The LINUS5 C uses microprocessors for controlling and monitoring the power amp This has four main advantages over...

Page 18: ...nnection LED 4 Standby power switch 9 Mains connection LED 5 Knurled grill screw LINUS5 C 2 THE AMPLIFIER 2 3 9 4 5 6 7 8 1 The rear 10 AC power connector 13 XLR Line inputs 11 SPEAKON connectors 14 E...

Page 19: ...nting the amplifier to the front rack rails For mobile use the amplifier should also be secured using the 19 mounting elements on the rear panel 483 00 452 00 424 60 442 00 443 00 465 00 88 10 76 2 0...

Page 20: ...y large breaker Always respect this rule of thumb for good installation practice for guaranteeing long term reliable robust and safe operation one LINUS5 C one circuit breaker As soon as the amplifier...

Page 21: ...systems Equipment with rated current 75 A and subject to conditional connection IEC 77A 929 CDV 2016 If in any doubt consult your local power provider Never attempt to measure this impedance level wit...

Page 22: ...3 6 green 2 7 brown white 4 8 brown 4 AES EBU RJ45 pin wiring RJ45 pin Colour Channel polarity 1 orange white 2 orange 3 green white 4 blue 3 4 5 blue white 3 4 6 green 7 brown white 1 2 8 brown 1 2 P...

Page 23: ...nd Centre SPEAKON Output Pin 1 Channel 1 amplifier output Pin 1 Channel 1 ground Pin 2 Channel 2 amplifier output Pin 2 Channel 2 ground Pin 3 Channel 3 amplifier output Pin 3 Channel 3 ground Pin 4 C...

Page 24: ...2 Select input Rotate the encoder knob to the point 01 SELECT INPUT Press the encoder knob to enter the input source selection Press and hold 1 channel selection button for the appropriate channel and...

Page 25: ...ction Press and hold 1 channel action button for the appropriate channel and rotate the encoder knob 2 Example shows chanel 1 selected with 1 00 ms delay Info You can select a larger scroll value by p...

Page 26: ...s 4 1 8 Set IP Rotate the encoder knob to the point 6 SET IP Press the encoder knob to enter IP Address Setup page Rotate the encoder knob 1 to select module number CHANGE IP address Press encoder 4 s...

Page 27: ...isplay will be provided by the manufacturer 4 1 10 System temperature Rotate the encoder knob to the point 8 SYSTEM TEMP Press the encoder knob to enter MODULE TEMPERATURE page 4 1 11 Backlight Rotate...

Page 28: ...3 2 Mains overvoltage detection There is NO overvoltage protection The customer needs to be sure to only use the LINUS5 C in the voltage range printed on the label on the back of the unit 4 4 Main SMP...

Page 29: ...should and may result in reduced output levels For changing the filter no additional tools are required First remove the knurled screw right next to the standby switch Then push the whole grill assem...

Page 30: ...eighted 117 dB A weighted Frequency response 8 load with CLEAR preset 20 Hz 20 kHz 0 5 dB 1 0 dB THD N 4 load 120 W output power 20 Hz 17 kHz 0 1 Latency input to loudspeaker output Minimum 2 70 ms AE...

Page 31: ...ption 1 4 power 150 W 4 to represent typical music signal Amplifier in standby 27 W Amplifier idle 115 W Amplifier power 851 W Input Input sources Analog AES EBU Analogue input impedance balanced 30 k...

Page 32: ...Maximum output voltage 85 V pk Maximum output current 38 A pk Damping factor 8 load 1 kHz and below 400 Minimum output load 2 nom Power output connections 2 x Neutrik NL4 speakON 1 x Neutrik NL8 spea...

Page 33: ...H x D 675 x 130 x 560 mm 26 57 x 5 12 x 22 05 Volume 0 049 m 1 73 ft Net weight 10 7 kg 23 6 lbs Shipping weight 14 kg 30 9 lbs Typical values some variation may exist due to component tolerances Volt...

Page 34: ...D N w AES17 filter 50 dBu 10 dBu 4 measurement of a typical performance Figure 6 3 THD N w AES17 filter 20 Hz 20 kHz 120 W output power 4 measurement of a typical performance 20 00 Hz 100 00 1000 00 1...

Page 35: ...of a typical performance Figure 6 5 Common mode rejection 20 Hz 20 kHz measurement of a typical performance 20 00 Hz 100 00 1000 00 10000 00 200 00 160 00 120 00 80 00 40 00 dBr 20 00 Hz 100 00 1000 0...

Page 36: ...ory approval service by an unauthorized service centre and normal wear and tear Amplifiers on which the serial number has been removed or defaced are not eligible for warranty service 7 3 What CODA Au...

Page 37: ...g address To transport the amplifier the original packing materials must be used Please return the amplifier to the following address or your nearest CODA Audio appointed distributor Nature of problem...

Page 38: ...of the amplifier it has to be checked regularly depending on its application but at least once a year by a properly qualified person Advice on how to carry out these checks can be found in DIN VDE 07...

Page 39: ...US5 C 11 NOTES NOTE IMPORTANT Please consider that any changes made to the amplifier have to be documented in writing and passed on to the buyer in the event of resale 11 NOTES CHANGES MADE TO THE AMP...

Reviews: