Coda 60.0 Operation Manuals Download Page 9

   

  8

TECHNICAL DATA

BRIDGED MONO

Rated Power

1000 Watts class AB @ 4 Ohms

Frequency Response:

 

DC to -3dB @ 100kHz

Distortion:

< .02 percent from 10Hz to 20kHz @ rated power

Gain:

32dB

Maximum Current:

> 100 Amperes peak

Noise:

-120dB reference to rated output

Input Impedance:

N/A unbalanced/10k Ohms balanced

Output Impedance:

.06 Ohms from 20Hz to 20kHz

POWER SUPPLY

Transformer Type:

Multi-tap, multi-winding toroidal

Transformer Rating:

3 kVA

Power Filtering:

184,000 

ì

F

DIMENSIONS

Height:

7” Faceplate, 7.75” Overall

Width:

18” Overall

Depth:

19” Overall

Weight:

110 lbs., 115 lbs. Shipping

Power Requirement:

1.5K Watts maximum at rated power

Summary of Contents for 60.0

Page 1: ...IFIER 60 0 MONO BALANCED AMPLIFIER 60 0 CODA TECHNOLOGIES INC BANK 1 2 3 10 SAFETY PRECAUTIONS INTRODUCTION DETAILED INSTALLATION DESIGN PHILOSOPHY TECHNICAL DATA CARE HANDLING WARRANTY DISCLAIMER WAR...

Page 2: ...RATURE ACCOMPANYING THE UNIT WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE TO AVOID ELECTRICAL SHOCK DO NOT OPEN THE UNIT REFER SERVICING TO QUALIFIED PERSONNEL N...

Page 3: ...rt to provide the listener with unmatched sound quality through superb design and construction Although its operation is fairly simple in order to operate your amplifier properly and to realize all of...

Page 4: ...nnecting cables while the amplifier is powered on could cause damage to your speakers 3 The AC line input should be connected to an AC outlet with the power cable provided with the amplifier 4 The fus...

Page 5: ...ables the amplifier by toggling the bias which enables the amplifier s outputs and switching shunting relays to mute the input 2 The rail status LEDs indicate that the positive and negative amplifier...

Page 6: ...er The power supply takes a very direct approach to high performance First top quality toridal transformers and over 184 000 uF of capacitance with very low ESR and inductance are used For optimum per...

Page 7: ...tering of all AC ripple These attributes result in an amplifier of such extreme linearity and bandwidth that no overall feedback correction is required or used One advantage of this is a high degree o...

Page 8: ...d wherever possible No electrolytic capacitors are used except in the power supply where several high capacitance electrolytics provide outstanding filtering of the supply output All semiconductor dev...

Page 9: ...ise 120dB reference to rated output Input Impedance N A unbalanced 10k Ohms balanced Output Impedance 06 Ohms from 20Hz to 20kHz POWER SUPPLY Transformer Type Multi tap multi winding toroidal Transfor...

Page 10: ...on Coda products When handling the unit take care not to mar the aluminum Aluminum is a medium hardness metal and can be scratched by the harder tool steels Avoid exposing the unit to direct sunlight...

Page 11: ...sole option IV Total Loss and Replacement If the product is submitted for service due to a severe malfunction which has caused damage sufficient enough to make a repair attempt infeasible the product...

Page 12: ...warranty service should it become necessary It is recommended that you retain a copy of this form for your own records Coda Technologies address and fax number are located on the back of this manual...

Page 13: ...7850 CUCAMONGA AVENUE 34 SACRAMENTO CA 95826 USA phone fax on the web at email us at 01 916 383 3653 01 916 455 3653 CODA CC info coda cc...

Reviews: